Related Experiment Video
Updated: May 2, 2026

Whole Animal Perfusion Fixation for Rodents
Published on: July 30, 2012
Comparison of routine fixation of tissues with rapid tissue fixation
Meenakshi Tripathi1, Rani Bansal2, Mamta Gupta3
1Post Graduate Student, Department of Pathology, Subharti University , Meerut, India .
Introduction:
Conventional formalin-fixed, paraffin-embedded tissue provides superior cellular morphology and long-term storage. Problems with formalin fixation comprise delay of fixation and variations in the duration of fixation. Microwave assisted tissue fixation removes the use of noxious and potentially toxic formalin that decreases the turnaround time and creates a personnel friendly workflow.
Material And Methods:
The present study was conducted over a period of two years. One hundred and forty paired tissue sections were taken including both neoplastic and non-neoplastic tissues. One of the paired tissues was fixed in formalin and the other was fixed by using microwave irradiation in phosphate buffered saline. Both were then processed by conventional method. Each slide was examined and rated for the adequacy of fixation by two pathologists in a blinded fashion using 7 parameters: Cellular outline, cytoplasmic detail, nuclear detail, erythrocyte integrity, lymphocyte appearance, overall morphology and overall staining.
Results:
Statistical analysis showed that sections obtained from microwave fixed tissues were comparable to that of routinely fixed tissue. The p-values of all parameters were not significant except for the overall morphology for which p-value was significant owing to loss of tissue in some cases.
Conclusion:
Microwave irradiation substantially shortened the time from specimen reception to diagnosis (turnaround time) and allowed same-day tissue processing and diagnosis of specimens without compromising the overall quality of the histologic section.
More Related Videos
09:03Rapid Freezing using Sandwich Freezing Device for Good Ultrastructural Preservation of Biological Specimens in Electron Microscopy
Published on: July 19, 2021
07:42Improved Swiss-rolling Technique for Intestinal Tissue Preparation for Immunohistochemical and Immunofluorescent Analyses
Published on: July 13, 2016
Related Concept Videos
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Simple Staining Technique