Aortic counterpulsation: C-pulse and other devices for cardiac support
1Division of Cardiology, Rutgers-New Jersey Medical School, 185 S. Orange Avenue, Newark, NJ, 07103, USA, solankpa@njms.rutgers.edu.
Journal of Cardiovascular Translational Research
|February 21, 2014
Summary
Heart failure remains a leading cause of hospitalization. The C-Pulse device offers a novel, non-blood-contacting counterpulsation therapy for advanced heart failure patients, providing long-term circulatory support.
Area of Science:
- Cardiology
- Biomedical Engineering
Background:
- Heart failure is a primary cause of hospitalization in the USA, with many patients progressing to advanced stages requiring mechanical circulatory support or heart transplantation.
- The shortage of donor hearts necessitates alternative therapies for end-stage heart failure.
- Counterpulsation therapy, a form of mechanical circulatory support, is widely used, with over 150,000 patients globally receiving it annually for conditions like cardiogenic shock.
Purpose of the Study:
- To provide an overview of different aortic counterpulsation devices.
- To focus on the C-Pulse device as a novel approach for advanced heart failure management.
- To highlight the C-Pulse device's potential for long-term circulatory support in symptomatic heart failure patients.
Main Methods:
- Review of existing counterpulsation therapies.
- Detailed examination of the C-Pulse device, an extra-aortic balloon (EAB) counterpulsation system.
- Description of the C-Pulse device's design for non-blood-contacting, partial circulatory support.
Main Results:
- The C-Pulse device is designed for permanent, long-term, continuous partial circulatory support.
- It targets New York Heart Association (NYHA) Class III and ambulatory Class IV heart failure patients.
- A pivotal multicenter US study is underway to evaluate the safety and efficacy of the C-Pulse device.
Conclusions:
- The C-Pulse device represents a novel extra-aortic balloon counterpulsation approach for advanced heart failure.
- It aims to manage patients who remain symptomatic despite optimal medical and device-based therapies.
- Further clinical evaluation is ongoing to establish its role in heart failure management.
More Related Videos
Related Concept Videos
Pulse
2.5K
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
2.5K
Pulse
4.0K
The pulse is one of the most fundamental physiological indicators of the body's cardiovascular health. It is the rhythmic expansion and contraction of the arterial walls in response to the pressure generated by the heart's pumping action.
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
4.0K
Equipments Used To Measure Blood Pressure
3.4K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.4K
Measurement of Blood Pressure
4.0K
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
4.0K
Pulse rhythm
1.7K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.7K
Assessment of apical radial pulse
1.6K
Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
1.6K