Patient body weight-tailored contrast medium injection protocol for the craniocervical vessels: a prospective
Rebecca Kessler1, Katrin Hegenscheid1, Steffen Fleck2
1Institute of Diagnostic Radiology and Neuroradiology, University Medicine Greifswald, Greifswald, Germany.
Objectives:
To evaluate body weight-tailored contrast medium (CM) administration for computed tomography angiography (CTA) of the craniocervical vessels.
Methods:
Institutional review board approval was obtained, and all patients gave written informed consent. Sixty patients were consecutively assigned to one of three dose groups (20 patients per group) with CM doses of Visipaque 270® (iodixanol 270 mg/ml) tailored to body weight at doses of 1.5, 1.0, or 0.5 ml/kg. Region-of-interest (ROI) analysis of maximum enhancement (ME) was conducted, and signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were calculated. Retrospective comparison was performed with three matched control groups examined with a standard CM dose (80 ml of Visipaque 270®). Image quality was rated by two neuroradiologists blinded to the CM dose used. Interrater reliability was calculated using kappa statistics.
Results:
Body weight/BMI and ME were inversely correlated in the three control groups receiving the standard dose (r = -0.544/-0.597/-0.542/r = -0.358/r = -0.424/r = -0.280). Compared to standard dose, 1.5 ml/kg produced higher ME, SNR, and CNR in the anterior circulation (p≤0.038), 1.0 ml/kg had higher ME in cervical and medium-sized cerebral arteries (p≤0.034), and 0.5 ml/kg had lower ME, SNR and CNR for medium-sized cerebral arteries (p≤0.049). ME, SNR, and CNR were the same for 1.5 ml/kg and 1.0 ml/kg (p≥0.24), and both had higher values compared to 0.5 ml/kg (p≤0.043/p≤0.028). In patients with BMI>25, 1.5 ml/kg and 1.0 ml/kg produced higher ME than standard dose (p<0.001/p = 0.008), but ME in patients with BMI>25 did not differ between group 1 and group 2 (p = 0.673). In patients with BMI≤25, 1.5 ml/kg and 1.0 ml/kg produced ME comparable to standard dose (p = 0.132/p = 0.403). Regardless of patient weight, 0.5 ml/kg yielded lower ME than standard dose (p = 0.019/0.002).
Conclusions:
Craniocervical CTA with a body weight-tailored CM dose of 1.0 ml/kg (270 mg iodine/ml) reduces iodine load in patients weighing <80 kg while producing ME similar to standard dose and improves ME in patients with BMI>25.
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies VII: Vascular Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...