Related Experiment Video
Updated: May 2, 2026

Author Spotlight: Point-of-Care Ultrasound for Gastric Content Assessment and Risk Stratification in Perioperative Care
Published on: September 22, 2023
Examination of accuracy in the assessment of gastric residual volume: a simulated, controlled study
Rebecca J Bartlett Ellis1, Joseph Fuehne2
1Indiana University School of Nursing at Indianapolis, Indiana rjbartle@iu.edu.
Background:
Increased gastric content from enteral nutrition intolerance is thought to place patients at risk for pulmonary aspiration. Although considered a questionable practice, blind gastric tube aspiration is the most common approach to measure gastric content. This simulated study evaluated the accuracy of residual volume (RV) assessment via tube aspirations made from known volumes by controlling the syringe pull technique, feeding tube properties, fluid viscosity, and placement of tubes in the fluid.
Materials And Methods:
This study was conducted in a metrology laboratory. Aspirates were obtained using a force measurement test system to control force of the syringe pull technique using 3 different procedures (slow 10 inches per minute [ipm], intermittent 10 ipm, and fast 40 ipm). Four different feeding tubes, 10 Fr and 18 Fr, each made of polyurethane and polyvinyl chloride, were placed in varying depths of 100 mL of either water or formula. The effect of fluid viscosity was also examined.
Results:
Overall, 108 RVs were analyzed using a force measurement test system. Actual content of RV was underestimated 19% on average and varied across tube size and viscosity. Intermittent and slow syringe pull techniques yielded greater aspirate quantities, although neither technique aspirated the full amount of volume available. The 10 Fr feeding tubes yielded larger RVs in more viscous fluid, yet the 18 Fr tubes performed better with fluids of lower viscosity.
Conclusions:
Based on this simulation, RV assessment does not accurately reflect the total volume of the contents available and, therefore, the clinical utility of this assessment should be further investigated.
More Related Videos
12:24Assessment of Gastric Emptying in Non-obese Diabetic Mice Using a [13C]-octanoic Acid Breath Test
Published on: March 23, 2013
08:22The Application of Point-of-Care Ultrasonography (POCUS) in the Management of Acute Respiratory Distress Syndrome (ARDS) in the Intensive Care Unit
Published on: December 12, 2025
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Gastric Emptying
Urodynamic Studies: Uroflowmetry
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of the Gastrointestinal System I: Subjective Data
Health History
The initial step in assessing the GI system is obtaining a comprehensive health history. This includes inquiring about the patient's history or presence of problems...