Related Experiment Video
Updated: May 2, 2026

Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
Very different external radiation doses in patients undergoing PET/CT or PET/MRI scans and factors affecting them
Ihn Ho Cho1, Eun Ok Han, Sang Tae Kim
1Department of Nuclear Medicine, Yeungnam University Hospital, Daegu 705-717, Korea. haneunok@gmail.com.
Abstract:
Our aim was to determine the external radiation dose rates of patients undergoing positron emission tomography/computed tomography (PET/CT) and PET/magnetic resonance imaging (MRI) examinations, and to assess the factors affecting these doses. The external radiation dose rates (ERDR) from (18)F-FDG were measured using the Geiger-Müller tube at a distance of 10, 50, and 100cm from the patients' skin surface from various body regions. Results showed that at 10cm from the body surface for PET/CT examinations, the ERDR immediately after (18)F-FDG i.v. injection at time points 1 and 4 was 522.19±189.59μSvh(-1) and 256.36±74.94μSvh(-1) , respectively. At 10cm from the body surface for PET/MRI examinations, the ERDR at time points 1 and 4 were 258.76±92.09μSvh(-1) and 105.63±27.48μSvh(-1), respectively, always with a precipitous decrease over time. The (18)F-FDG dose was on average 1.93-fold higher and the ERDR was higher approximately 2.01 to 2.42-fold in PET/CT examinations than in PET/MRI examinations. In both PET/CT and PET/MRI patients, the ERDR was significantly higher with lower body weight, shorter stature, and fewer urinations etc. In conclusion, based on our results, the ERDR to patients from PET/CT scans at a distance of 10cm was twice as high than from the PET/MRI. Furthermore, to decrease ERDR to the patients, the dose injected should be adjusted to body weight and height. Factors like post injection fluid intake and urine bladder emptying, decrease ERDR. Other persons should keep a safe distance from the injected patient.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...