Methods for evaluating temporal trends in noise exposure
R L Neitzel1, D Galusha, C Dixon-Ernst
1* Department of Environmental Health Sciences and Risk Science Center, University of Michigan , Ann Arbor , USA.
Objective:
Hearing conservation programs have been mandatory in many US industries since 1983. Since then, three program elements (audiometric testing, hearing protection, and training) have been the focus of much research. By comparison, little has been done on noise exposure evaluation.
Design:
Temporal trends in time weighted average (TWA) exposures and the fraction of measurements exceeding 85 dBA were evaluated by facility, by exposure group within facility, and by individual worker within facility.
Study Sample:
A large dataset (> 10 000 measurements over 20 years) from eight facilities operated by a multinational aluminum manufacturing company was studied.
Results:
Overall, exposures declined across locations over the study period. Several facilities demonstrated substantial reductions in exposure, and the results of mean noise levels and exceedance fractions generally showed good agreement. The results of analyses at the individual level diverged with analyses by facility and exposure group within facility, suggesting that individual-level analyses, while challenging, may provide important information not available from coarser levels of analysis.
Conclusions:
Validated metrics are needed to allow for assessment of temporal trends in noise exposure. Such metrics will improve our ability to characterize, in a standardized manner, efforts to reduce noise-induced hearing loss.
More Related Videos
07:13Modified Experimental Conditions for Noise-Induced Hearing Loss in Mice and Assessment of Hearing Function and Outer Hair Cell Damage
Published on: February 10, 2023
06:01Semi-Automated Analysis of Peak Amplitude and Latency for Auditory Brainstem Response Waveforms Using R
Published on: December 9, 2022
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...