Related Experiment Video
Updated: May 2, 2026

Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
The height for screw index (HSI) predicts the development of C2 nerve dysfunction associated with C1 lateral mass
Da-Geng Huang1, Ding-Jun Hao, Yong-Hong Jiang
1Department of Spine Surgery, Honghui Hospital, Xi'an Jiaotong University College of Medicine, No. 76 Nanguo Road, Xi'an, 710054, Shaanxi, People's Republic of China, hdgrichard@sina.com.
Purpose:
To propose a new measure, the height for screw index (HSI), as a predictor of C2 nerve dysfunction in patients who have received posterior C1 lateral mass screw (C1LMS) fixation for atlantoaxial instability and to examine whether the HSI scores correlated with the development of C2 nerve dysfunction through retrospective analysis of 104 C1LMS inserted in 52 patients with atlantoaxial instability.
Methods:
The medical records of patients who underwent C1LMS fixation were retrospectively reviewed. C1LMS, 3.5 mm in diameter, was inserted for atlantoaxial stabilization. The sagittal plane of the planned C1LMS trajectory was reconstructed from CT images. The HSI was defined as the difference in height between C2 ganglion and its corresponding foramen. C2 nerve function was assessed using a validated visual analog scale questionnaire. Each foramen receiving C1LMS was considered as a single unit and patients were categorized to group 1, HSI ≥4.0 mm; group 2, HSI <4.0 mm.
Results:
The mean HSI score was 4.7 ± 0.8 mm (range 3.1-6.5 mm) with 85 (81.7 %) units in group 1, and 19 (18.3 %) units in group 2. Fourteen (13.5 %, 14/104) units developed C2 nerve dysfunction. C2 nerve dysfunction was reported in 4 units in group 1, and 10 units in group 2, respectively. The percentage of C2 nerve dysfunction was significantly higher in group 2 than that in group 1 (P < 0.001, Pearson Chi-square test).
Conclusions:
The HSI score correlates with the development of C2 nerve dysfunction in patients receiving C1LMS fixation for atlantoaxial instability and may be a useful predictor of C2 nerve dysfunction.
Related Concept Videos
Articulations of the Vertebral Column
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...