Related Experiment Video
Updated: May 2, 2026

Microelectrode Array Recording of Sinoatrial Node Firing Rate to Identify Intrinsic Cardiac Pacemaking Defects in Mice
Published on: July 5, 2021
T-type channels in the sino-atrial and atrioventricular pacemaker mechanism
Pietro Mesirca1, Angelo G Torrente, Matteo E Mangoni
1Département de Physiologie, Institut de Génomique Fonctionnelle, LabEx ICST, 34094, Montpellier, France.
Abstract:
Cardiac automaticity is a fundamental physiological function in vertebrates. Heart rate is under the control of several neurotransmitters and hormones and is permanently adjusted by the autonomic nervous system to match the physiological demand of the organism. Several classes of ion channels and proteins involved in intracellular Ca(2+) handling contribute to pacemaker activity. Voltage-dependent T-type Ca(2+) channels are an integral part of the complex mechanism underlying pacemaking. T-type channels also contribute to impulse conduction in mice and humans. Strikingly, T-type channel isoforms are co-expressed in the cardiac conduction system with other ion channels that play a major role in pacemaking such as f- (HCN4) and L-type Cav1.3 channels. Pharmacologic inhibition of T-type channels reduces the spontaneous activity of isolated pacemaker myocytes of the sino-atrial node, the dominant heart rhythmogenic centre. Target inactivation of T-type Cav3.1 channels abolishes I Ca,T in both sino-atrial and atrioventricular myocytes and reduces the daily heart rate of freely moving mice. Cav3.1 channels contribute also to automaticity of the atrioventricular node and to ventricular escape rhythms, thereby stressing the importance of these channels in automaticity of the whole cardiac conduction system. Accordingly, loss-of-function of Cav3.1 channels contributes to severe form of congenital bradycardia and atrioventricular block in paediatric patients.
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Mechanism of Cardiac Arrhythmias
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Electrophysiology of Normal Cardiac Rhythm
G-Protein Gated Ion Channels
Sensory...

