Related Experiment Video
Updated: May 2, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Analysis of amphetamine-type substances and piperazine analogues using desorption electrospray ionisation mass
Natasha Stojanovska1, Tamsin Kelly, Mark Tahtouh
1Centre for Forensic Science, University of Technology, Sydney (UTS), PO Box 123, Broadway, NSW, 2007, Australia.
Rationale:
Although amphetamine-type substances (ATS) have been investigated extensively in recent years, scarce data is available on screening tests for piperazine analogues. The need for a universal technique capable of detecting an extensive range of drug compounds becomes increasingly important with the continued emergence of novel drug analogues.
Methods:
Desorption electrospray ionisation mass spectrometry (DESI-MS) is a technique that allows examination of compounds in drug materials directly from ambient surfaces. In this study, DESI-MS was utilised in the analysis of ATS including amphetamine (AP), methylamphetamine (MA), 3,4-methylenedioxymethylamphetamine (MDMA), N,N-dimethylamphetamine (DMA), 4-methoxyamphetamine (PMA) and 4-methoxymethylamphetamine (PMMA), and piperazine analogues including 1-benzylpiperazine (BZP), 1-[3-(trifluoromethyl)phenyl]piperazine (TFMPP), 1-(3-chlorophenyl)piperazine (mCPP) and 1-(4-methoxyphenyl)piperazine (MeOPP). Semi-porous polytetrafluoroethylene (PTFE or Teflon) sheets welled with a 3 mm hole punch were used to contain the 2 μL liquid sample (spot size 7 mm(2) ).
Results:
The limits of detection (LODs) of these compounds using DESI-MS were determined to be in the range 0.02-2.80 µg/mm(2) . The intra-day and inter-day precision of the technique were <25% and <33%, respectively. DESI-MS was successful in determining the compound of interest and reaction by-products and impurities in the samples tested (such as 1,4-dibenzylpiperazine in BZP samples) with the exception of those present in trace amounts. The effects of common adulterants on the detectability of MA were evaluated. The addition of magnesium stearate to MA significantly enhanced the signal response.
Conclusions:
This work has demonstrated the applicability of DESI-MS in the screening and profiling of MDMA, PMMA, BZP, TFMPP, mCPP, MeOPP as well as other complex mixtures.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
11:14Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Amine Fragmentation
In amines, the number of nitrogen atoms affects the mass of the molecular ion, which is described by the nitrogen rule of mass spectrometry. This rule states that a compound containing...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrum: Interpretation
Mass Spectrometry of Amines
Tandem Mass Spectrometry