Development of a sensitive LC/MS/MS method for vitamin D metabolites: 1,25 Dihydroxyvitamin D2&3 measurement using a
Curtis J Hedman1, Donald A Wiebe2, Subhakar Dey3
1Institute of Clinical and Translational Research, University of Wisconsin, Madison, WI, USA; Wisconsin National Primate Research Center, University of Wisconsin, Madison, WI, USA; Wisconsin State Laboratory of Hygiene, University of Wisconsin, Madison, WI, USA.
Abstract:
Active vitamin D metabolites 1,25-dihydroxyvitamin D2 [1,25-(OH)2-D2; derived from ergocalciferol] and D3 [1,25-(OH)2-D3; derived from cholecalciferol] are found in low levels in the circulation and require a very sensitive method for measurement. Radioimmunoassay (RIA) has been the method of choice, but it lacks the specificity needed to distinguish between 1,25-(OH)2-D2 and -D3, whereas liquid chromatography-tandem mass spectrometry (LC/MS/MS) methods have the advantage of high specificity and sensitivity. Here, we compare a new derivative for ionizing 1,25-(OH)2-D to enhance the signal and provide the most sensitive assay for measuring vitamin D. We used the Amplifex diene method of derivatizing prior to LC/MS/MS and compared it to the standard RIA method and the 4-phenyl-1,2,4-triazole-3,5-dione (PTAD) method of derivatizing prior to LC/MS/MS. In the evaluation of 20 human serum samples, all methods correlated strongly across the upper levels of the standard 1,25-(OH)2-D2 and -D3 ranges (Amplifex and RIA, pc=0.97; Amplifex and PTAD, pc=0.96) but less strongly on the lower levels of the standard range (Amplifex and RIA, pc=0.81; Amplifex and PTAD, pc=0.65) suggesting differences in the sensitivities between the assays. The Amplifex method was determined to be more sensitive than the PTAD method, as peak areas were significantly higher for the Amplifex method and provided for a 10 fold higher signal-to-noise ratio than PTAD. Therefore, the Amplifex LC/MS/MS method is the most sensitive and specific method available for measuring 1,25-(OH)2-D2 and -D3 while using the smallest sample volume.
More Related Videos
05:03Author Spotlight: Investigating Physiological Functions of Vitamin A Transporters Using HPLC-Based Vitamin A Profiling
Published on: December 27, 2024
08:06Absolute Quantification of Cell-Free Protein Synthesis Metabolism by Reversed-Phase Liquid Chromatography-Mass Spectrometry
Published on: October 25, 2019