Related Experiment Video
Updated: May 2, 2026

Subcutaneous Neurotrophin 4 Infusion Using Osmotic Pumps or Direct Muscular Injection Enhances Aging Rat Laryngeal Muscles
Published on: June 13, 2017
Office-based vocal fold injection with the laryngeal introducer technique
Matthew S Clary1, Benjamin M Milam, Mark S Courey
1Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado.
Objectives/Hypothesis:
There are numerous techniques for awake laryngeal injection, each with its limitations and technical challenges. We demonstrate a modification to the thyrohyoid approach for injection that stabilizes needle introduction and allows for consistent placement in a wide variety of larynges.
Study Design:
Retrospective review at a tertiary care institution.
Methods:
A retrospective review was performed of the charts for patients consecutively undergoing awake vocal fold injection laryngoplasty in 2013 for glottic insufficiency due to unilateral vocal fold paralysis, vocal fold atrophy, or sulcus vocalis using the laryngeal introducer technique. The consistency of needle placement, ease of technique, and patient tolerance was assessed. The technique utilizes a curved 1.5-inch 18-gauge needle as a laryngeal introducer through the thyroid notch. Laryngeal injection augmentation is then performed using a curved 3.5-inch 25-gauge spinal needle through the introducer.
Results:
Twenty-one patients were identified who underwent awake vocal fold injection laryngoplasty for glottic insufficiency. All 21 injections were successfully placed. Five of seven injections attempted by resident physicians were able to be completed without attending assistance. Patient experience data demonstrated good tolerance, with a preference for the awake procedure as compared to that performed under general anesthesia.
Conclusions:
The laryngeal introducer technique is a novel way of performing awake laryngeal injections. It provides a high rate of success, the ability to be consistently performed by inexperienced clinicians, and is well tolerated by patients.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Suctioning the Nasopharyngeal Airway
Equipment Required
Cardiopulmonary Resuscitation II: ACLS Airway Management
Larynx
Anatomy of the Larynx
The larynx consists of various components, including cartilage, muscles, and vocal cords. Its structure includes three large unpaired cartilages—the thyroid, cricoid, and epiglottis—and three smaller paired cartilages—the arytenoids,...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...

