Related Experiment Video
Updated: May 2, 2026

Design and Optimization Strategies of a High-Performance Vented Box
Published on: June 9, 2023
Improving flow patterns and spillage characteristics of a box-type commercial kitchen hood
Rong Fung Huang1, Jia-Kun Chen, Meng-Ji Han
1a Department of Mechanical Engineering , National Taiwan University of Science and Technology , Taipei , Taiwan , Republic of China.
Abstract:
A conventional box-type commercial kitchen hood and its improved version (termed the "IQV commercial kitchen hood") were studied using the laser-assisted smoke flow visualization technique and tracer-gas (sulfur hexafluoride) detection methods. The laser-assisted smoke flow visualization technique qualitatively revealed the flow field of the hood and the areas apt for leakages of hood containment. The tracer-gas concentration detection method measured the quantitative leakage levels of the hood containment. The oil mists that were generated in the conventional box-type commercial kitchen hood leaked significantly into the environment from the areas near the front edges of ceiling and side walls. Around these areas, the boundary-layer separation occurred, inducing highly unsteady and turbulent recirculating flow, and leading to spillages of hood containment due to inappropriate aerodynamic design at the front edges of the ceiling and side walls. The tracer-gas concentration measurements on the conventional box-type commercial kitchen hood showed that the sulfur hexafluoride concentrations detected at the hood face attained very large values on an order of magnitude about 10(3)-10(4) ppb. By combining the backward-offset narrow suction slot, deflection plates, and quarter-circular arcs at the hood entrance, the IQV commercial kitchen hood presented a flow field containing four backward-inclined cyclone flow structures. The oil mists generated by cooking were coherently confined in these upward-rising cyclone flow structures and finally exhausted through the narrow suction slot. The tracer-gas concentration measurements on the IQV commercial kitchen hood showed that the order of magnitude of the sulfur hexafluoride concentrations detected at the hood face is negligibly small--only about 10(0) ppb across the whole hood face.
Related Concept Videos
Laminar Flow: Problem Solving
Design Example: Flow Through a Fire Extinguisher
The key to understanding how the...
Laminar Flow
Steady, Laminar Flow Between Parallel Plates
Design Example: Flow of Oil Through Circular Pipes
Steady, Laminar Flow in Circular Tubes