Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Reproducibility of aortic pulse wave velocity as assessed with the new Complior Analyse
Telmo Pereira1, João Maldonado, Ivo Andrade
1aDepartment of Cardiopneumology, Coimbra Polytechnic Institute, ESTEC bInstitute of Cardiovascular Research, Coimbra, Portugal.
Introduction:
The aim of this study was to assess the interobserver and intraobserver reproducibility, as well as the temporal variability of the new Complior Analyse assessing aortic pulse wave velocity (PWV).
Methods:
Eighty-seven participants (60% men), mean age 34.26 ± 16.58 years, were enrolled in a cross-sectional study. All patients were subjected to sequential measures of aortic PWV by two experienced operators. In a group of 27 participants, PWV was also determined 1 month after the first moment evaluation to assess the temporal stability of the PWV estimations with the device.
Results:
The analysis of concordance showed a very good agreement for paired PWV values in terms of both the intraobserver and the interobserver variability and also the temporal variability. The intraclass correlation coefficients were above 0.98 for the three conditions (P<0.0001), indicating an excellent strength of agreement. Further evidences in favor of a good overall performance of the device were determined from the Bland-Altman analysis, with small mean differences for intrareproducibility, interreproducibility, and temporal reproducibility (respectively, 0.02 ± 0.38, 0.10 ± 0.45, and 0.07 ± 0.51 m/s), and with differences mainly between 2 SDs of the mean difference. The correlations observed were independent of sex, age, arterial pressure, heart rate, and BMI.
Conclusion:
The data showed an excellent reproducibility of the Complior Analyse for the assessment of aortic PWV when used in ideal conditions and by experienced observers. The technical profile presented shows that this device meets the requirements of quality for its inclusion in integrated clinical follow-up programs.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: