Cycling-off modes during pressure support ventilation: effects on breathing pattern, patient effort, and comfort
Fabrícia C Hoff1, Mauro R Tucci2, Marcelo B P Amato2
1Intensive Care Unit, Hospital Mãe de Deus, Porto Alegre, Brazil; Graduate Program in Medical Sciences, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil.
Purpose:
Expiratory asynchrony during pressure support ventilation (PSV) has been recognized as a cause of patient discomfort, increased workload, and impaired weaning process. We evaluated breathing pattern, patient comfort, and patient effort during PSV comparing 2 flow termination criteria: fixed at 5% of peak inspiratory flow vs automatic, real-time, breath-by-breath adjustment within the range of 5% to 55%.
Materials And Methods:
Randomized crossover clinical trial. Sixteen awake patients, in the process of weaning, under PSV for more than 24 hours were subjected to 3 phases of PSV, each lasting 1 hour and using 1 of the 2 aforementioned termination criteria.
Results:
Effective pressure support during automatic adjustment (AA) was 12.5±3.2 cm H2O vs 12.5±3.9 cm H2O (P=.9) with the fixed termination criterion, and external positive end-expiratory pressure was 6.2±1.8 vs 6.8±2 (P<.05). The effective termination criterion was higher during AA (31% [23-39] vs 12% [6-23]; P<.01), but without producing premature breath terminations. Pressure overshoots and alternative cycling-off were also decreased. Throughout the AA period, we observed a higher respiratory rate (24±8 breaths/min vs 19±6 breaths/min; P<.001), lower tidal volume (484 ± 88 mL vs 518±102 mL; P<.001), and shorter inspiratory times (1.0±0.3 seconds vs 1.3±0.3 seconds; P<.001). Automatic adjustment was associated with lower airway occlusion pressure after 0.1 second (P0.1) (1.8±0.9 cm H2O vs 2.4±1 cm H2O; P<.01), lower pressure-time product to trigger the ventilator, and lower subjective discomfort (visual analog scale, 3.7±1.3 vs 4.5±1.2; P<.001).
Conclusions:
When compared with a fixed termination criterion, the use of a variable, real-time-adjusted termination criterion improved some indices of patient-ventilator synchrony, producing better breathing pattern, less discomfort, and slightly lower patient effort during PSV.
More Related Videos
08:34Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Related Concept Videos
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: