Indocyanine green fluorescence-guided sentinel node biopsy: a meta-analysis on detection rate and diagnostic
L Xiong1, E Gazyakan1, W Yang2
1Department of Hand, Plastic and Reconstructive Surgery, Burn Center, BG Trauma Center Ludwigshafen, University of Heidelberg, Ludwig Guttmann Str. 13, 67071 Ludwigshafen, Germany.
Background:
Indocyanine green (ICG) fluorescence-guided sentinel node biopsy (SLNB) has been successfully employed in various kinds of tumors. Clinical results of previous studies on this technique are at different levels of evidence. This Meta-analysis was conducted to provide a more precise estimation on its clinical performance.
Methods:
Eligible studies were identified from systematical PubMed and EMBASE searches; data were extracted. A Meta-analysis was performed to generate pooled detection rate, sensitivity, specificity, diagnostic odds ratio (DOR) and summary receiver operator characteristic curves.
Results:
Fifteen published articles were included. Clinical data of 513 patients were obtained. The pooled detection rate, the pooled sensitivity, the pooled specificity, the pooled DOR and their 95% confidence intervals (95% CI) were 0.96 (0.91-0.99), 0.87 (0.79-0.92), 1.00 (0.99-1.00) and 150.13 (57.42-392.56), respectively. Significant heterogeneities existed among studies. Significant publication bias was found in detection rate. The concentration < 5 mg/ml subgroup and the injected volume ≥2 ml subgroup had higher DORs, sensitivities and detection rates than the concentration ≥ 5 mg/ml subgroup and the injected volume <2 ml subgroup, respectively.
Conclusion:
Based on this Meta-analysis, this technique could be valued promising for detecting the presence of LN metastases. ICG injection with reduced concentration and larger volume may provide improved performance.