Requirements for static and dynamic higher order B0 shimming of the human breast at 7 T
Vincent O Boer1, Mariska P Luttje, Peter R Luijten
1Department of Radiology, University Medical Center Utrecht, the Netherlands.
Abstract:
The increased magnetic susceptibility effects at higher magnetic fields increase the demands for shimming of the B0 field for in vivo MRI and MRS. Both static and dynamic techniques have been developed to compensate for susceptibility-induced field inhomogeneities. In this study, we investigate the impact of and need for both static and dynamic higher order B0 shimming of magnetic field homogeneities in clinical breast MRI at 7 T. Both global and local field variations at lipid-tissue interfaces were observed in the magnetic field using TE-optimized B0 mapping at 7 T. With static B0 shimming, a field homogeneity of 39 ± 11 Hz (n = 48) was reached in a single breast using second-order shimming. Further compensation of the residual local field inhomogeneities caused by lipid-tissue interfaces does not seem to be feasible with shallow spherical harmonic fields. For bilateral shimming, the shimming quality was significantly less at 62 ± 15 Hz (n = 22) over both breasts, even after (simulated) fourth-order shimming. In addition, a substantial time-dependent field instability of 30 Hz peak to peak, with significant higher order field contributions, was observed during regular breathing. In conclusion, TE-optimized B0 field mapping reveals substantial field variations in the lipid-rich environment of the human breast, in both space and time. The static field variations could be partially minimized by third-order B0 shimming, providing sufficient lipid suppression. However, in order to fully benefit from the increased spectral dispersion at high fields, the significant magnetic field variations during breathing need to be considered.
Related Concept Videos
08:33Microfluidic Device for the Separation of Non-Metastatic (MCF-7) and Non-Tumor (MCF-10A) Breast Cancer Cells Using AC Dielectrophoresis
08:31Versatility of Protocols for Resistance Training and Assessment Using Static and Dynamic Ladders in Animal Models
10:51Modeling Breast Cancer in Human Breast Tissue using a Microphysiological System
09:14Cardiac Magnetic Resonance Imaging at 7 Tesla
Requirements for Human Life
Oxygen
Atmospheric air is only about 20 percent oxygen, but that oxygen is a key component of the chemical reactions that keep the body alive, including the reactions that produce ATP. Brain cells are susceptible to a lack of oxygen because they require a...
Static, Stagnation, Dynamic and Total Pressure