The use of pulse wave velocity in predicting pre-eclampsia in high-risk women

Irene Katsipi1, Kostas Stylianou1, Ioannis Petrakis1

  • 1Department of Nephrology, University Hospital of Heraklion, Heraklion, Crete, Greece.

In this study, we evaluated the diagnostic utility of pulse wave velocity (PWV) alone or in combination with other diagnostic markers in predicting pre-eclampsia (PE) in high-risk women. Pregnant women at high risk for PE were recruited between 22 and 26 weeks of gestation and were assessed for (a) PWV, (b) serum levels of the placental soluble fms-like tyrosine kinase 1 (sFlt-1) protein and uric acid and (c) 24-h urinary protein and calcium excretion. Sensitivities and specificities were derived from receiver operating characteristic curves. Of 118 women recruited, 11 and 10 women developed early-onset PE (<34 weeks) and late-onset PE (≥34 weeks), respectively. Of the five diagnostic markers tested, PWV showed the highest detection rate for all cases (21) of PE (81%) and for early-onset PE (82%) at a fixed 10% false-positive rate (FPR), and when combined with sFlt-1, these figures increased to 90% and 92%, respectively. Despite the reduced ability of PWV to predict late-onset PE (detection rate 20%), the combination of PWV with sFlt-1 achieved a detection rate of 50% at a fixed 10% FPR. A suggested cutoff value of 9 m/s for PWV resulted in optimal sensitivity (91%) and specificity (86%) for predicting early-onset PE. This study is the first to show that PWV may be a potentially promising predictor of early-onset PE in women at high risk for PE. The combination of PWV with sFlt-1 may further improve the screening efficacy for predicting PE.

Related Concept Videos

Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
3.0K
Pulse01:16

Pulse

When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
2.5K
Pre-Procedural Guidelines for Assessing Blood Pressure01:10

Pre-Procedural Guidelines for Assessing Blood Pressure

Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
880
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
2.1K
Pulse rhythm01:30

Pulse rhythm

Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.7K
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.4K