The use of pulse wave velocity in predicting pre-eclampsia in high-risk women
Irene Katsipi1, Kostas Stylianou1, Ioannis Petrakis1
1Department of Nephrology, University Hospital of Heraklion, Heraklion, Crete, Greece.
In this study, we evaluated the diagnostic utility of pulse wave velocity (PWV) alone or in combination with other diagnostic markers in predicting pre-eclampsia (PE) in high-risk women. Pregnant women at high risk for PE were recruited between 22 and 26 weeks of gestation and were assessed for (a) PWV, (b) serum levels of the placental soluble fms-like tyrosine kinase 1 (sFlt-1) protein and uric acid and (c) 24-h urinary protein and calcium excretion. Sensitivities and specificities were derived from receiver operating characteristic curves. Of 118 women recruited, 11 and 10 women developed early-onset PE (<34 weeks) and late-onset PE (≥34 weeks), respectively. Of the five diagnostic markers tested, PWV showed the highest detection rate for all cases (21) of PE (81%) and for early-onset PE (82%) at a fixed 10% false-positive rate (FPR), and when combined with sFlt-1, these figures increased to 90% and 92%, respectively. Despite the reduced ability of PWV to predict late-onset PE (detection rate 20%), the combination of PWV with sFlt-1 achieved a detection rate of 50% at a fixed 10% FPR. A suggested cutoff value of 9 m/s for PWV resulted in optimal sensitivity (91%) and specificity (86%) for predicting early-onset PE. This study is the first to show that PWV may be a potentially promising predictor of early-onset PE in women at high risk for PE. The combination of PWV with sFlt-1 may further improve the screening efficacy for predicting PE.
In this study, we evaluated the diagnostic utility of pulse wave velocity (PWV) alone or in combination with other diagnostic markers in predicting pre-eclampsia (PE) in high-risk women. Pregnant women at high risk for PE were recruited between 22 and 26 weeks of gestation and were assessed for (a) PWV, (b) serum levels of the placental soluble fms-like tyrosine kinase 1 (sFlt-1) protein and uric acid and (c) 24-h urinary protein and calcium excretion. Sensitivities and specificities were derived from receiver operating characteristic curves. Of 118 women recruited, 11 and 10 women developed early-onset PE (<34 weeks) and late-onset PE (≥34 weeks), respectively. Of the five diagnostic markers tested, PWV showed the highest detection rate for all cases (21) of PE (81%) and for early-onset PE (82%) at a fixed 10% false-positive rate (FPR), and when combined with sFlt-1, these figures increased to 90% and 92%, respectively. Despite the reduced ability of PWV to predict late-onset PE (detection rate 20%), the combination of PWV with sFlt-1 achieved a detection rate of 50% at a fixed 10% FPR. A suggested cutoff value of 9 m/s for PWV resulted in optimal sensitivity (91%) and specificity (86%) for predicting early-onset PE. This study is the first to show that PWV may be a potentially promising predictor of early-onset PE in women at high risk for PE. The combination of PWV with sFlt-1 may further improve the screening efficacy for predicting PE.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...