Carbon paste electrode modified with cuo-nanoparticles as a probe for square wave voltammetric determination of
Nadereh Rahbar1, Hooshang Parham2
1Nanotechnology Research Center, School of Pharmacy, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, IR Iran ; Department of Medicinal Chemistry, School of Pharmacy, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, IR Iran.
Background:
Atrazine (ATZ) is a widely used herbicide in most countries because of its low cost and good selectivity. The concentration of ATZ that the EPA considers safe to consume in drinking water is 3 ppb. Therefore, recently, there have been concerns about its determination in trace levels. This compound is not electro-active, so in this research indirect electrochemical method for its detection in low levels was proposed.
Objectives:
The main aim of this study is the indirect determination of ATZ in water samples by voltammetry using nano-particle modified electrode.
Materials And Methods:
A nano-CuO modified carbon paste electrode (NMCPE) is constructed and its application for indirect square wave voltammetric (SWV) detection of ATZ is reported. The sensing performance mechanism of the nano-CuO modified carbon paste electrode toward atrazine is due to complexation of the analyte with Cu (II) ion. The peak current for copper (II) reduction decreases with increase in the ATZ concentration and is monitored for its determination. Instrumental and chemical parameters influencing the detection of ATZ were optimized.
Results:
The results revealed that decrease in peak current was proportional to ATZ concentration over the range of 5-75 ng/mL. The limit of detection (LOD) and limit of quantification (LOQ) were 2 ng/mL and 5.6 ng/mL (n = 20), respectively. The relative standard deviation (n = 10) for the determination of 10 and 50 ng/mL of ATZ solution was estimated as 4.9% and 4.2 %, respectively.
Conclusions:
This easily fabricated electrode together with the fast and sensitive SW voltammetry was successfully applied for the determination of concentration of ATZ at trace levels, in different water samples.
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Cyclic Voltammetry
Controlled-Current Coulometry: Overview
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...