Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Optimizing Chromatographic Separations01:15

Optimizing Chromatographic Separations

1.3K
Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
1.3K
Size-Exclusion Chromatography01:08

Size-Exclusion Chromatography

2.8K
In size-exclusion chromatography (SEC), also known as molecular-exclusion or gel-permeation chromatography, molecules are separated based on their sizes. This technique is important for separating large molecules such as polymers and biomolecules. The two classes of micron-sized stationary phases encountered in SEC are silica particles and cross-linked polymer resin beads. Both materials are porous, but their pore sizes vary significantly.
Silica particles offer advantages such as rigidity,...
2.8K
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

1.9K
Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
1.9K
Precipitation and Co-precipitation01:17

Precipitation and Co-precipitation

4.8K
Precipitation and coprecipitation methods can be used to separate a mixture of ions in a solution. In qualitative inorganic analysis, ions that form sparingly soluble precipitates with the same reagent are separated based on the differences in solubility products. For example, consider the separation of Cu(II) and Fe(II) ions by precipitation as insoluble sulfides. First, copper(II) sulfide is precipitated by the addition of acidic H2S, where the dissociation of H2S is suppressed. Adding H2S...
4.8K
Centrifugation01:05

Centrifugation

6.9K
Centrifugation is a separation technique based on differences in density or size. It is commonly used to separate solids from aqueous interferents. During centrifugation, the sample is placed in centrifugation tubes and spun at high angular velocity, which allows centrifugal force to act differentially on the different densities or masses of the components. After spinning, the supernatant liquid is decanted. Depending on the specific application, either the pellet or the supernatant is retained...
6.9K
Dialysis01:15

Dialysis

2.1K
Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
2.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Conformational active peptides for antiviral therapy.

Bioorganic chemistry·2026
Same author

Lifetime of liquid junction free reference electrodes with polymeric membranes as a function of lipophilicity and diffusion parameters. Updated theory.

Talanta·2025
Same author

Lipophilicity Criteria for Ionic Components Used in Liquid-Junction-Free Reference Electrodes.

Analytical chemistry·2025
Same author

H<sup>+</sup>-Selective Electrodes Based on Amine-Type Ionophores: Generalized Theory and A Priori Quantification of Lower and Upper Detection Limits.

ACS sensors·2023
Same author

Matrix is everywhere: extracellular DNA is a link between biofilm and mineralization in Bacillus cereus planktonic lifestyle.

NPJ biofilms and microbiomes·2023
Same author

A feasible, fast and reliable method for estimating ion-site association constants in plasticized PVC ion-selective electrode membranes.

Analytica chimica acta·2023

Related Experiment Video

Updated: May 2, 2026

Online Size-exclusion and Ion-exchange Chromatography on a SAXS Beamline
11:09

Online Size-exclusion and Ion-exchange Chromatography on a SAXS Beamline

Published on: January 5, 2017

16.6K

Improved separate solution method for determination of low selectivity coefficients.

Vladimir V Egorov1, Elena A Zdrachek, Valentine A Nazarov

  • 1Department of Analytical Chemistry, Belarusian State University , Leningradskaya str., 14, 220030 Minsk, Belarus.

Analytical Chemistry
|March 15, 2014
PubMed
Summary

A new experimental method accurately determines low selectivity coefficients by analyzing their time-dependent behavior. This approach offers reliable results, improving upon existing methods for ion-selective electrode analysis.

More Related Videos

Sulfate Separation by Selective Crystallization with a Bis-iminoguanidinium Ligand
08:01

Sulfate Separation by Selective Crystallization with a Bis-iminoguanidinium Ligand

Published on: September 8, 2016

7.6K
Curtain Flow Column: Optimization of Efficiency and Sensitivity
06:44

Curtain Flow Column: Optimization of Efficiency and Sensitivity

Published on: June 12, 2016

6.3K

Related Experiment Videos

Last Updated: May 2, 2026

Online Size-exclusion and Ion-exchange Chromatography on a SAXS Beamline
11:09

Online Size-exclusion and Ion-exchange Chromatography on a SAXS Beamline

Published on: January 5, 2017

16.6K
Sulfate Separation by Selective Crystallization with a Bis-iminoguanidinium Ligand
08:01

Sulfate Separation by Selective Crystallization with a Bis-iminoguanidinium Ligand

Published on: September 8, 2016

7.6K
Curtain Flow Column: Optimization of Efficiency and Sensitivity
06:44

Curtain Flow Column: Optimization of Efficiency and Sensitivity

Published on: June 12, 2016

6.3K

Area of Science:

  • Analytical Chemistry
  • Electrochemistry

Background:

  • The separate solution method (SSM) for determining selectivity coefficients in ion-selective electrodes is known to yield time-dependent results, particularly for low coefficients.
  • Existing methods like the modified separate solution method (MSSM) have limitations, including restrictions on electrode conditioning.

Discussion:

  • This study introduces a novel, theoretically grounded experimental method for determining improved selectivity coefficients.
  • The method leverages the linear dependence of SSM-determined selectivity coefficients on time raised to a negative power (specifically, time to the minus one-fourth for equally charged ions).
  • Extrapolation of these time-dependent data to zero time (Y-axis intersection) provides accurate low selectivity coefficients, often in the range of n x 10(-7).

Key Insights:

  • Accurate determination of low selectivity coefficients (down to n x 10(-7)) is achievable through time-dependent data extrapolation.
  • The proposed method overcomes the electrode conditioning limitations of MSSM, allowing for repeated measurements after primary ion conditioning.
  • Results obtained by this new method align well with those from MSSM but are free from its inherent constraints.

Outlook:

  • This method offers a faster and more robust alternative for characterizing ion-selective electrode performance.
  • Further validation across a wider range of ion combinations and electrode types is warranted.
  • Potential applications include improved sensor development and more precise chemical analysis.