Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Stent Edge-Related Hematoma: An Overlooked Predictor of Early Stent Failure.

JACC. Cardiovascular interventions·2026
Same author

Efficacy of the Shear Stress Pattern Computed in Coronary Artery Reconstruction Models With and Without Side Branches in Predicting Plaque Progression.

Arteriosclerosis, thrombosis, and vascular biology·2026
Same author

Comparison of Atheroma Burden Changes Using Conventional vs. End-Diastolic Intravascular Ultrasound Segmentation - Post Hoc Analysis of the PACMAN-AMI Study.

Circulation journal : official journal of the Japanese Circulation Society·2026
Same author

A novel framework for fully automated co-registration of intravascular ultrasound and optical coherence tomography imaging data.

European heart journal. Digital health·2026
Same author

IntraCross: Cross-modality graph matching for intravascular sequence registration.

Computers in biology and medicine·2026
Same author

Preclinical serial shear stress analysis of a novel strut-free fibrillated bioresorbable polymeric endoluminal graft.

Frontiers in cardiovascular medicine·2026

Related Experiment Video

Updated: May 2, 2026

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
05:31

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model

Published on: June 8, 2022

2.7K

Evolution of transcatheter aortic valve replacement.

Christos V Bourantas1, Patrick W Serruys

  • 1From the Department of Interventional Cardiology, ThoraxCenter, Erasmus Medical Center, Rotterdam, The Netherlands (C.V.B., P.W.S.); and International Centre for Circulatory Health, National Heart and Lung Institute, Imperial College London, London, United Kingdom (P.W.S.).

Circulation Research
|March 15, 2014
PubMed
Summary

Transcatheter aortic valve replacement (TAVR) has revolutionized structural cardiology over 20 years. Ongoing advancements address limitations and expand TAVR applications, improving patient outcomes.

Keywords:
aortic valve stenosisprognosis

More Related Videos

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
06:04

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation

Published on: August 8, 2025

722
Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
08:50

Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement

Published on: March 26, 2018

10.9K

Related Experiment Videos

Last Updated: May 2, 2026

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
05:31

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model

Published on: June 8, 2022

2.7K
Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
06:04

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation

Published on: August 8, 2025

722
Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
08:50

Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement

Published on: March 26, 2018

10.9K

Area of Science:

  • Cardiology
  • Interventional Cardiology
  • Medical Technology

Background:

  • Transcatheter aortic valve replacement (TAVR) emerged approximately 20 years ago, significantly impacting structural interventional cardiology.
  • Early animal studies and initial clinical results demonstrated the feasibility and promise of percutaneous valve implantation.
  • Subsequent industry and scientific efforts over the past 12 years have focused on refining TAVR technology and procedures.

Purpose of the Study:

  • To review the historical evolution of transcatheter aortic valve replacement (TAVR).
  • To present the foundational steps and early evidence in the field of TAVR.
  • To discuss current limitations and future directions for TAVR development.

Main Methods:

  • Review of historical data, including early experiments in animal models.
  • Analysis of evidence from clinical trials and patient registries.
  • Discussion of technological advancements and proposed solutions for TAVR limitations.

Main Results:

  • TAVR has evolved significantly over two decades, transforming treatment for aortic valve disease.
  • Initial promising results have driven substantial innovation to overcome technical challenges.
  • Registries and trials provide evidence supporting TAVR's expanding role and efficacy.

Conclusions:

  • Transcatheter aortic valve replacement represents a major advancement in cardiology.
  • Continued research and development are crucial for addressing TAVR's limitations and enhancing its application.
  • Future perspectives in TAVR aim to improve safety, broaden indications, and optimize patient care.