Related Experiment Video
Updated: May 2, 2026

Photoelectron Imaging of Anions Illustrated by 310 Nm Detachment of F−
Published on: July 27, 2018
Rovibronic structure in slow photoelectron velocity-map imaging spectroscopy of CH2CN⁻ and CD2CN⁻
Marissa L Weichman1, Jongjin B Kim1, Daniel M Neumark1
1Department of Chemistry, University of California, Berkeley, California 94720, USA.
Abstract:
We report high-resolution anion photoelectron spectra of the cryogenically cooled cyanomethide anion, CH2CN(-), and its isotopologue, CD2CN(-), using slow photoelectron velocity-map imaging (SEVI) spectroscopy. Electron affinities of 12 468(2) cm(-1) for CH2CN and 12 402(2) cm(-1) for CD2CN are obtained, demonstrating greater precision than previous experiments. New vibrational structure is resolved for both neutral species, especially activity of the ν5 hydrogen umbrella modes. The ν6 out-of-plane bending mode fundamental frequency is measured for the first time in both systems and found to be 420(10) cm(-1) for CH2CN and 389(8) cm(-1) for CD2CN. Some rotational structure is resolved, allowing for accurate extraction of vibrational frequencies. Temperature-dependent SEVI spectra show marked effects ascribed to controlled population of low-lying anion vibrational levels. We directly measure the inversion splitting between the first two vibrational levels of the anion ν5 umbrella mode in both species, finding a splitting of 130(20) cm(-1) for CH2CN(-) and 81(20) cm(-1) for CD2CN(-). Franck-Condon forbidden activity is observed and attributed to mode-specific vibrational autodetachment from the CH2CN(-) and CD2CN(-) dipole bound excited states. We also refine the binding energy of the anion dipole bound states to 39 and 42 cm(-1), respectively, for CH2CN(-) and CD2CN(-).
More Related Videos
Related Concept Videos
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...