Conversion factors for determining organ doses received by paediatric patients in high-resolution single slice
Michael C Seidenbusch1, Dietrich Harder2, Dieter F Regulla3
1Paediatric Radiology, Institute for Clinical Radiology, Dr. von Hauner's Children's Hospital, Ludwig-Maximilians-University Munich, Lindwurmstr. 4, 80337 Munich, Germany.
Abstract:
Estimations of organ doses DT received during computed tomographic examinations are usually performed by applying conversion factors to basic dose indicators like the computed tomography dose index (CTDI) or the dose-length-product (DLP). In addition to the existing conversion factors for beam apertures of 5 mm or 10 mm, we present new DLP-DT conversion factors adapted to high-resolution CT (HRCT) examinations of infants and young children with beam apertures of the order of 1 mm and under consideration of bow tie filtration. Calculations are performed on mathematical MIRD phantoms for an age range from 0, 1, 5, 10, 15 up to (for comparison) 30 years by adapting PCXMC, a Monte Carlo algorithm originally developed by STUK (Helsinki, Finland) for dose reconstructions in projection radiography. For this purpose, each single slice CT examination is approximated by a series of corresponding virtual planar radiographies comprising all focus positions. The transformation of CT exposure parameters into exposure parameters of the series of corresponding planar radiographies is performed by a specially developed algorithm called XCT. The DLP values are evaluated using the EGSRay code. The new method is verified at a beam aperture of 10 mm by comparison with formerly published conversion factors. We show that the higher spatial resolution leads to an enhanced DLP-DT conversion factor if a small organ (e. g. thyroid gland, mammae, uterus, ovaries, testes) is exactly met by the chosen CT slice, while the conversion factor is drastically reduced if the chosen CT slice is positioned above or below the organ. This effect is utilized for dose-saving examinations with only a few single slices instead a full scan, which technique is applied in about 10% of all paediatric chest CT examinations.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Drug Dosing: Infants and Children
Biological Effects of Radiation