Observational study of changes in epidural pressure and elastance during epidural blood patch in obstetric patients
S D Pratt1, D W Kaczka1, P E Hess1
1Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Beth Israel Deaconess Medical Center, Boston, MA, USA.
Background:
During an epidural blood patch, we inject blood until the patient describes mild back pressure, often leading to injection of more than 20 mL of blood. We undertook this study to measure the epidural pressures generated during an epidural blood patch and to identify the impact of volume on epidural elastance in obstetric patients.
Methods:
This study was performed in postpartum patients who presented for an epidural blood patch with symptoms consistent with a postdural puncture headache. After identification of the epidural space using loss of resistance to air or saline, we measured static epidural pressure after each 5-mL injection of blood. Models were then fitted to the data and the epidural elastance and compliance calculated.
Results:
Eighteen blood patches were performed on 17 patients. The mean final volume injected was 18.9±7.8 mL [range 6-38 mL]. The mean final pressure generated was 13.1±13.4 mmHg [range 2-56 mmHg]. A curvilinear relationship existed between volume injected and pressure, which was described by two models: (1) pressure=0.0254×(mL injected)(2)+0.0297 mL, or (2) pressure=0.0679×mL(1.742). The value for r2 was approximately 0.57 for both models. We found no correlation between the final pressure generated and the success of the epidural blood patch.
Conclusions:
We found a curvilinear relationship between the volume of blood injected during an epidural blood patch and the pressure generated in the epidural space. However, there was a large variation in both the volume of blood and the epidural pressure generated. The clinical importance of this finding is not known. A larger study would be required to demonstrate whether pressure is a predictor of success.
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: