Purpose:
The use of an extracellular matrix scaffold (ECM) combined with platelets to enhance healing of an anterior cruciate ligament (ACL) graft ("bio-enhanced ACL reconstruction") has shown promise in animal models. However, the effects of platelet concentration on graft healing remain unknown. The objectives of this study were to determine whether increasing the platelet concentration in the ECM scaffold would (1) improve the graft biomechanical properties and (2) decrease cartilage damage after surgery.
Methods:
Fifty-five adolescent minipigs were randomized to five treatment groups: untreated ACL transection (n = 10), conventional ACL reconstruction (n = 15) and bio-enhanced ACL reconstruction using 1× (n = 10), 3× (n = 10) or 5× (n = 10) platelet-rich plasma. The graft biomechanical properties, anteroposterior (AP) knee laxity, graft histology and macroscopic cartilage integrity were measured at 15 weeks.
Results:
The mean linear stiffness of the bio-enhanced ACL reconstruction procedure using the 1× preparation was significantly greater than traditional reconstruction, while the 3× and 5× preparations were not. The failure loads of all the ACL-reconstructed groups were equivalent but significantly greater than untreated ACL transection. There were no significant differences in the Ligament Maturity Index or AP laxity between reconstructed knees. Macroscopic cartilage damage was relatively minor, though significantly less when the ECM-platelet composite was used.
Conclusions:
Only the 1× platelet concentration improved healing over traditional ACL reconstruction. Increasing the platelet concentration from 1× to 5× in the ECM scaffold did not further improve the graft mechanical properties. The use of an ECM-platelet composite decreased the amount of cartilage damage seen after ACL surgery.
More Related Videos
07:51Effects of Allogeneic Platelet-Rich Plasma PRP on the Healing Process of Sectioned Achilles Tendons of Rats: A Methodological Description
Published on: March 19, 2018
08:30Surgical Retrieval, Isolation and In vitro Expansion of Human Anterior Cruciate Ligament-derived Cells for Tissue Engineering Applications
Published on: April 30, 2014
Related Concept Videos
Formation of the Platelet Plug
As the injured blood vessel contracts, endothelial cells undergo contraction, revealing collagen fibers in the basement membrane and underlying connective tissue. Furthermore, the plasma membrane of endothelial cells becomes adhesive, preparing the site for platelet adhesion. Platelets...
Clot Retraction and Fibrinolysis