Post-retentive ability of new flowable resin composites
Related Experiment Video
Updated: May 2, 2026

Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
Purpose:
To investigate the applicability of flowable composites as post luting agents by assessing the push-out strength of posts.
Methods:
36 intact single rooted human premolars were selected. The endodontic treatment was performed and half of the specimens were restored with light transmitting posts (DT Light Post Illusion) and the other half with opaque posts (Tech 21 X-OP). In both groups the following combinations of adhesive/cement were tested: OptiBond Solo Plus/Nexus Third Generation (NX3), XP Bond/SureFil SDR Flow (SDR), and Vertise Flow (VF). Push-out test was used to assess the retentive strength of fiber posts, which was expressed in megapascals (MPa). Specimens were analyzed under a stereomicroscope to determine failure mode (adhesive between luting agent and post, adhesive between luting agent and dentin or mixed failure). Push-out data and failure mode distribution were analyzed by two-way ANOVA and Chi-square test, respectively (P< 0.05).
Results:
The statistical analysis revealed that only the type of luting material significantly influenced push-out bond strength of the post (P< 0.001). SDR (9.00 +/- 2.17 MPa) performed similarly to the control group NX3 (7.15 +/- 1.74 MPa), while VF (4.81 +/- 1.51 MPa) should significantly lower bond strength. Failure modes differed significantly among groups.
More Related Videos
Related Concept Videos
Flow Table Test
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Mortar Properties
Retarders
The function of retarders is to delay the setting of concrete, and this effect can be measured using a penetration test. The retardation process involves adding...
Porosity in Cement Paste
The balance of water to cement in the mix is...