Performance of the Japanese glomerular filtration rate equation based on standardized serum cystatin C in potential kidney donors
Related Experiment Video
Updated: May 1, 2026

Assessment of Kidney Function in Mouse Models of Glomerular Disease
Published on: June 30, 2018
M Horio1, Y Yasuda2, J Kaimori3
1Department of Functional Diagnostic Science, Osaka University Graduate School of Medicine, Osaka, Japan.
Background:
It was reported that the glomerula filtration rate (GFR) equation based on serum creatinine underestimated the GFR in potential kidney donors. Recently, the Japanese GFR equation based on standardized serum cystatin C was reported. Therefore, we assessed the performance of the equation in potential kidney donors.
Methods:
Forty-five potential kidney donors from 2 hospitals were included. GFR was measured (mGFR) using inulin renal clearance. Serum creatinine was measured using the enzymatic method. Serum cystatin C was measured using a nephelometric immunoassay (Siemens) and calibrated to the standardized value traceable to ERM-DA471/IFCC using an equation reported previously. The estimated GFR (eGFR) was calculated using the Japanese GFR equation based on serum creatinine (eGFRcreat) and the Japanese GFR equation based on serum cystatin C (eGFRcys). Bias (mGFR - eGFR) and accuracy (P30) of the equations were evaluated.
Results:
Inulin clearance, eGFRcreat, and eGFRcys were 91.0 ± 18.2, 78.5 ± 18.8, and 93.3 ± 16.3 mL/min/1.73 m(2), respectively. Bias of eGFRcreat was 12.4 ± 15.8 mL/min/1.73 m(2) and significantly different from zero, indicating underestimation of GFR. Bias of eGFRcys was -2.3 ± 16.3 mL/min/1.73 m(2) and was not significantly different from zero, suggesting better performance. But, the precision (standard deviation [SD] of bias) and accuracy (P30: Percentage of participants with eGFR within 30% of mGFR) of eGFRcys were not better compared with eGFRcreat. Accuracies (P30) of eGFRcreat and eGFRcys were 87% (95% confidence interval [CI], 74-94) and 82% (95% CI, 69-91), respectively.
Conclusion:
Bias of eGFRcys was better compared with eGFRcreat. But, the precision (SD of bias) and accuracy of eGFRcys were not superior compared with eGFRcreat in potential kidney donors.
Related Concept Videos
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Serum Studies: Renal Function Tests
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Glomerular Filtration Rate and its Regulation
GFR regulation involves two primary intrinsic controls: the myogenic and tubuloglomerular feedback mechanisms.
The myogenic...