Assessment of heat generation during implant insertion
Mahmut Sumer1, Ilker Keskiner2, Ugur Mercan3
1Associate Professor, Department of Oral and Maxillofacial Surgery, University of Ondokuz Mayis, Faculty of Dentistry, Samsun, Turkey.
Statement Of Problem:
Many studies have investigated the heat generated during implant preparation, but data are needed to better predict heat generation during implant insertion.
Purpose:
The purpose of this study was to measure the heat generated during insertion of an implant at speeds of 30, 50, and 100 rpm, and with manual insertion.
Material And Methods:
Sixty-four uniform fresh bovine femoral cortical bone specimens were used. After the cortical bone was drilled, 3 different implant insertion speeds and the manual insertion of the implant were evaluated for 2 different implant diameters. The temperature was measured with 2 Teflon-insulated, type K thermocouples. Data were analyzed by 2-way ANOVA, and the Tukey honestly significant difference test (α=.05).
Results:
The highest thermal change for 4.1-mm-diameter implants was found at a speed of 100 rpm (9.81°C ±2.29°C), and the lowest thermal change was 3.69°C ±0.85°C at a speed of 30 rpm. A statistically significant difference was found between 100 rpm and the other 3 insertion procedures. The highest thermal change for a 4.8-mm-diameter implant was found at a speed of 100 rpm (8.79°C ±1.53°C), and the lowest thermal change was 4.48°C ±0.85°C at a speed of 30 rpm. No statistical difference was observed with manual, 30 rpm, and 50 rpm; however, a statistically significant difference was found between 100 rpm and the other 3 insertion procedures.
Conclusions:
Manual implant insertion and at speeds of 30 rpm and 50 rpm generated lower heat compared with insertion at 100 rpm.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...