Assessing the persistence, bioaccumulation potential and toxicity of brominated flame retardants: data availability

Greta Stieger1, Martin Scheringer1, Carla A Ng1

  • 1Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland.

Chemosphere
|March 25, 2014
PubMed

Related Concept Videos

Flame Photometry: Overview01:02

Flame Photometry: Overview

Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
2.0K
Toxicity Testing in Animals01:23

Toxicity Testing in Animals

Toxicity tests in animals are grounded on two main assumptions: first, the effects observed in laboratory animals can be extrapolated to humans, especially when adjusted for body surface area; second, high-dose exposure in animals is essential to identify potential human hazards from lower doses. This is based on the quantal dose-response concept, which faces the challenge of extrapolating results from relatively few test animals to much larger human populations. For example, a 0.01% incidence...
204
Halogenation of Alkenes02:46

Halogenation of Alkenes

Halogenation is the addition of chlorine or bromine across the double bond in an alkene to yield a vicinal dihalide. The reaction occurs in the presence of inert and non-nucleophilic solvents, such as methylene chloride, chloroform, or carbon tetrachloride.
Consider the bromination of cyclopentene. Molecular bromine is polarized in the proximity of the π electrons of cyclopentene. An electrophilic bromine atom adds across the double bond, forming a cyclic bromonium ion intermediate.
17.1K
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
1.3K