Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Enhancing gas chromatography-time of flight mass spectrometry data analysis using two-dimensional mass channel
Brian D Fitz1, Brooke C Reaser, David K Pinkerton
1Department of Chemistry, University of Washington , Box 351700, Seattle, Washington 98195, United States.
Abstract:
A novel data reduction and representation method for gas chromatography time-of-flight mass spectrometry (GC-TOFMS) is presented that significantly facilitates separation visualization and analyte peak deconvolution. The method utilizes the rapid mass spectral data collection rate (100 scans/s or greater) of current generation TOFMS detectors. Chromatographic peak maxima (serving as the retention time, tR) above a user specified signal threshold are located, and the chromatographic peak width, W, are determined on a per mass channel (m/z) basis for each analyte peak. The peak W (per m/z) is then plotted against its respective tR (with 10 ms precision) in a two-dimensional (2D) format, producing a cluster of points (i.e., one point per peak W versus tR in the 2D plot). Analysis of GC-TOFMS data by this method produces what is referred to as a two-dimensional mass channel cluster plot (2D m/z cluster plot). We observed that adjacent eluting (even coeluting) peaks in a temperature programmed separation can have their peak W vary as much as ∼10-15%. Hence, the peak W provides useful chemical selectivity when viewed in the 2D m/z cluster plot format. Pairs of overlapped analyte peaks with one-dimensional GC resolution as low as Rs ≈ 0.03 can be visually identified as fully resolved in a 2D m/z cluster plot and readily deconvoluted using chemometrics (i.e., demonstrated using classical least-squares analysis). Using the 2D m/z cluster plot method, the effective peak capacity of one-dimensional GC separations is magnified nearly 40-fold in one-dimensional GC, and potentially ∼100-fold in the context of comparing it to a two-dimensional separation. The method was studied using a 73 component test mixture separated on a 30 m × 250 μm i.d. RTX-5 column with a LECO Pegasus III TOFMS.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
11:14Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Mass Spectrum: Interpretation
MALDI-TOF Mass Spectrometry
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...