Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Measurement of oxygen concentration delivered via nasal cannulae by tracheal sampling
Andrew O'Reilly Nugent1, Paul T Kelly, Josh Stanton
1Respiratory Physiology Laboratory, Christchurch Hospital, Christchurch, New Zealand.
Background And Objective:
Oxygen is used in many clinical scenarios, however the variable performance of nasal cannulae makes determining the precise fraction of inspired oxygen (FiO2 ) difficult. We developed a novel method for measurement of the tracheal FiO2 using a catheter placed via bronchoscopy. We investigate the effects of oxygen delivery, respiratory rate, mouth position and estimated minute ventilation (VE ) on the FiO2 delivered by nasal cannulae.
Methods:
The catheter was placed in 20 subjects. Tracheal gas concentrations were analysed during six 5-min treatments controlling for oxygen delivery rate, respiratory rate and mouth position. Ventilation was monitored with respiratory inductive plethysmography (RIP). The FiO2 delivered by nasal cannulae was compared between treatments, and we investigated the relationships among the FiO2 , alveolar partial pressure of oxygen (PA O2 ) and VE .
Results:
The FiO2 increased by 0.038/L/min of oxygen. Respiratory rate had a significant effect on the FiO2 . A normal respiratory rate of 15 breaths/min and oxygen supplementation via nasal cannula at 2 L/min resulted in an FiO2 of 0.296; however, FiO2 decreased by 0.012 at 20 breaths/min and 0.004 at 10 breaths/min. The mean FiO2 decreased by 0.024 with the mouth open. The FiO2 and PA O2 were observed to decrease with increasing VE .
Conclusions:
Continuous measurement of the FiO2 using a transtracheal catheter provides detailed insight into inspiratory changes of the FiO2 delivered by nasal cannulae. Our study confirms that respiratory rate, VE and mouth position significantly influence the inspired oxygen concentration. These parameters should be accounted for when prescribing oxygen.
More Related Videos
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...