Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Automated dispersive liquid-liquid microextraction-gas chromatography-mass spectrometry
1Department of Chemistry, National University of Singapore , 3 Science Drive 3, Singapore 117543, Singapore.
Abstract:
An innovative automated procedure, low-density solvent based/solvent demulsification dispersive liquid-liquid microextraction (automated DLLME) coupled to gas chromatography-mass spectrometry (GC/MS) analysis, has been developed. The most significant innovation of the method is the automation. The entire procedure, including the extraction of the model analytes (phthalate esters) by DLLME from the aqueous sample solution, breaking up of the emulsion after extraction, collection of the extract, and analysis of the extract by GC/MS, was completely automated. The applications of low-density solvent as extraction solvent and the solvent demulsification technique to break up the emulsion simplified the procedure and facilitated its automation. Orthogonal array design (OAD) as an efficient optimization strategy was employed to optimize the extraction parameters, with all the experiments conducted auotmatically. An OA16 (4(1) × 2(12)) matrix was initially employed for the identification of optimized extraction parameters (type and volume of extraction solvent, type and volume of dispersive solvent and demulsification solvent, demulsification time, and injection speed). Then, on the basis of the results, more levels (values) of five extraction parameters were investigated by an OA16 (4(5)) matrix and quantitatively assessed by the analysis of variance (ANOVA). Enrichment factors of between 178- and 272-fold were obtained for the phthalate esters. The linearities were in the range of 0.1 and 50 μg/L and 0.2 and 50 μg/L, depending on the analytes. Good limits of detection (in the range of 0.01 to 0.02 μg/L) and satisfactory repeatability (relative standard deviations of below 5.9%) were obtained. The proposed method demonstrates for the first time integrated sample preparation by DLLME and analysis by GC/MS that can be operated automatically across multiple experiments.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
High-Performance Liquid Chromatography: Types of Detectors
Tandem Mass Spectrometry
Matrix-Assisted Laser Desorption Ionization (MALDI)