Related Experiment Video
Updated: May 1, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Polyvinylimidazole/sol-gel composite as a novel solid-phase microextraction coating for the determination of
Manoochehr Farjaminezhad1, Mohammad Saber Tehrani, Parviz Aberoomand Azar
1Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran, Iran.
Abstract:
A polyvinylimidazole/sol-gel composite is proposed as a novel solid-phase microextraction fiber to extract five halobenzenes from the headspace of aqueous solutions in combination with gas chromatography with mass spectrometry. The prepared fiber was characterized by scanning electron microscopy and Fourier transform infrared spectroscopy. The obtained results showed that porous polyvinylimidazole/sol-gel composite was chemically deposited on fused silica fiber. The effect of important extraction parameters including extraction temperature, extraction time, and salt content were investigated. The optimum conditions were as follows: extraction temperature 25°C, extraction time 20 min, and salt concentration 30 w/v%. Detection limits and relative standard deviations of the developed method for halogenated benzenes were below 0.1 pg/mL and 15%, respectively. Repeatability of the proposed method, explained by relative standard deviation, varied between 5.48 and 9.15% (n = 5). The limits of detection (S/N = 3) ranged between 0.01 and 0.10 ng/L using gas chromatography with mass spectrometry with selected ion monitoring mode. For real sample analysis, three types of water samples with different matrices (ground, surface, and tap water) were studied. The optimized procedure was applied to extraction and method validation of halogenated benzenes in spiked water samples.
More Related Videos
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
04:39A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Related Concept Videos
Extraction: Advanced Methods
Reactions at the Benzylic Position: Halogenation
Ion-Exchange Chromatography
Nucleophilic Aromatic Substitution: Elimination–Addition
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...