Application of artificial palpation in vascular surgeries for detection of peripheral arterial stenosis
A Abouei Mehrizi1, M Moini, E Afshari
1Biomechanics Lab, Life Science Engineering Department, Faculty of New Sciences and Technologies, University of Tehran , Amir Abad, North Kargar Street, Tehran , Iran .
Abstract:
Palpation is one of the applied methods that surgeons usually use during surgery in order to verify the health condition of a tissue/organ. In fact, most of surgical assessments are based on analysis of the force feedback received from tissue/organ via palpation. Although palpation has a key role in efficient progress of surgery operations, it depends very much on the experience and skill of the surgeons. This limits the application of this technique in some cases to a large extent. In this regard, an artificial tactile sensing approach is an innovative technology that tries to make tactile data more available for surgeons, especially in situations where doing the palpation is not possible or is too difficult. In this paper, having considered the present problems of artery bypass surgery in peripheral arterial occlusive disease (PAOD), applicability of a new tactile sensory system capable of detecting arterial stenosis during surgery was evaluated. Presenting the modelling and numerical solution of the problem, it was demonstrated that the artificial tactile sensing approach is not only capable of detecting the presence of an arterial stenosis in an artery, but also its type. Furthermore, it was shown that the new tactile sensory system (previously designed, fabricated and tested in laboratory) is efficiently capable of detecting the simulated artery in the simulated biological tissue as well as diagnosis of the stenosis occurred inside it.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Artery Disease V: Postoperative Nursing Management
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Peripheral Artery Disease III: Interprofessional Care
Assessment of the Abdomen III: Palpation