Calcium carbonate breath test for non-invasive estimation of gastric acid secretion
Hirohiko Shinkai1, Katsunori Iijima, Tomoyuki Koike
1Division of Gastroenterology, Tohoku University Graduate School of Medicine.
Abstract:
Gastric acid measurement is useful in assessing the effectiveness of antisecretory drugs, however, the conventional tests involve invasive nasogastric intubation. Orally administered ¹³C-labeled calcium carbonate (Ca¹³CO₃) reacts with gastric acid to produce ¹³C-labeled carbon dioxide (¹³CO₂), which is then excreted in the breath. The objective of this study was to evaluate the suitability of Ca¹³CO3 breath test for estimating gastric acid secretion in human noninvasively. First, the Ca¹³CO₃ breath test and the measurement of pooled gastric acid under a fasting condition were performed in 6 healthy volunteers to evaluate the correlation between the two parameters. Next, endoscopic gastric acid collection and the Ca¹³CO₃ breath test were performed on different days after pentagastrin injection in 20 subjects to evaluate the correlation between the tests and the reproducibility. Finally, the same studies were repeated in 4 subjects before and after 1-week rabeprazole, a proton pump inhibitor, administration. The maximum CO₂ concentration (Cmax) correlated very well with the amount of pooled gastric acid (r = 0.95), suggesting that Ca¹³CO₃ breath test values well reflected the fasting intragastric acidity. The ¹³CO₂ concentration after pentagastrin injection correlated well with pentagastrin-stimulated maximal acid output (r = 0.79 at 20 min). The reproducibility of the Ca¹³CO₃ breath test under pentagastrin-stimulation was good (coefficient of variation = 0.11). Rabeprazole administration markedly reduced the values of the Ca¹³CO₃ breath test, suggesting that it can sensitively assess the efficacy of rabeprazole. The Ca¹³CO₃ breath test can potentially be a useful method for non-invasive estimation for gastric acid secretion in human.
Related Concept Videos
Serum Laboratory Studies, Stool Test, Breath Test
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acid Suppressive Drugs for Peptic Ulcer Disease: Antacids
However, this neutralization reaction between...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Respiratory Regulation of Acid-Base Balance
When carbon dioxide levels increase in the blood, more H+ and HCO3⁻ are...