Rapid detection of terbufos in stomach contents using desorption electrospray ionization mass spectrometry
Christina R Wilson1, Christopher C Mulligan2, Kurt D Strueh2
1Department of Comparative Pathobiology, School of Veterinary Medicine (Wilson, Hooser), Purdue University, West Lafayette, INAnimal Disease Diagnostic Laboratory (Wilson, Hooser), Purdue University, West Lafayette, INDepartment of Chemistry, Illinois State University, Normal, IL (Mulligan)Frankfort Animal Hospital, Frankfort, IN (Strueh)Veterinary Diagnostic & Production Animal Medicine, Ames, IA (Stevenson) wilsonc@purdue.edu.
Abstract:
Desorption electrospray ionization mass spectrometry (DESI-MS) is an emerging analytical technique that permits the rapid and direct analysis of biological or environmental samples under ambient conditions. Highlighting the versatility of this technique, DESI-MS has been used for the rapid detection of illicit drugs, chemical warfare agents, agricultural chemicals, and pharmaceuticals from a variety of sample matrices. In diagnostic veterinary toxicology, analyzing samples using traditional analytical instrumentation typically includes extensive sample extraction procedures, which can be time consuming and labor intensive. Therefore, efforts to expedite sample analyses are a constant goal for diagnostic toxicology laboratories. In the current report, DESI-MS was used to directly analyze stomach contents from a dog exposed to the organophosphate insecticide terbufos. The total DESI-MS analysis time required to confirm the presence of terbufos and diagnose organophosphate poisoning in this case was approximately 5 min. This highlights the potential of this analytical technique in the field of veterinary toxicology for the rapid diagnosis and detection of toxicants in biological samples.
More Related Videos
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Tandem Mass Spectrometry
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Performance Liquid Chromatography: Types of Detectors
