Related Experiment Video
Updated: May 1, 2026

Image Acquisition using Portable Sonography for Emergency Airway Management
Published on: September 28, 2022
A new instrument to assess physician skill at chest tube insertion: the TUBE-iCOMPT
Matthew R Salamonsen1, Farzad Bashirzadeh1, Alexander J Ritchie2
1Department of Thoracic Medicine, The Royal Brisbane and Women's Hospital, Brisbane, Australia.
Abstract:
Currently no tool exists to assess proceduralist skill at chest tube insertion. As inadequate doctor procedural competence has repeatedly been associated with adverse events, there is a need for a tool to assess procedural competence. This study aims to develop and examine the validity of a tool to assess competency at insertion of a chest tube, using either the Seldinger technique or blunt dissection. A 5-domain 100-point assessment tool was developed inline with British Thoracic Society guidelines and international consensus—the Chest Tube Insertion Competency Test (TUBE-iCOMPT). The instrument was used to assess chest tube insertion in mannequins and live patients. 29 participants (9 novices, 14 intermediate and 6 advanced) were tested by 2 blinded expert examiners on 2 occasions. The tool's validity was examined by demonstrating: (1) stratification of participants according to expected level of expertise (analysis of variance), and (2) test-retest and intertester reliability (intraclass correlation coefficient). The intraclass correlation coefficient of repeated scores for the Seldinger technique and blunt dissection, were 0.92 and 0.91, respectively, for test-retest results, and 0.98 and 0.95, respectively, for intertester results. Clear stratification of scores according to participant experience was seen (p<0.0001). There was no significant difference between scores obtained using mannequins or live patients. This study has validated the TUBE-iCOMPT, which could now be incorporated into chest tube insertion training programmes, providing a way to document acquisition of skill, guide individualised teaching, and assist with the assessment of the adequacy of clinician training.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...

