Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
A sensitive, rapid and inexpensive method to assess aluminium(III) ions in technetium eluates
Federica E Buroni1, Lorenzo Lodola, Marco G Persico
1Nuclear Medicine Unit, IRCCS San Matteo Hospital Foundation, Pavia, Italy.
Abstract:
The aim of the study was to validate a semiquantitative analytical method to identify the aluminium(III) [Al(III)] concentration in 99Mo/99mTc generator eluates to check the European Pharmacopoeia (Ph. Eur.) requirement (<5 μg/ml). Three different solutions measuring 20 ml - 0.2% 1,10-phenanthroline, 0.05% chrome azurol S and 20% hexamethylenetetramine - were prepared. A cellulose filter paper was subsequently immersed in them, dried overnight at room temperature and cut into rectangles. A volume of 5 μl of first eluates of various 99Mo/99mTc generators was placed onto a reagent paper and the spot colour was compared with a standard aluminium solutions scale (0-100 μg/ml). A cyan/magenta/yellow/key (CMYK) model analysis was adapted to quantify the intensity of colour on the paper, and the presence of aluminium in the eluates was detected by a spectrophotometer. Small changes in standard solution pH (4.1-5.2) and chrome azurol S concentration did not affect the analysis. The cyan channel image analysis was proportional to the Al3+ solution concentration (y=25 019x+1489, R2=0.9554 within 2.5-8 μg/ml). The detection limit for aluminium by the visual test method is about 1 μg/ml, and fading is absent. The cyan channel image analysis method is independent of the observer and is applicable for the evaluation of the chemical purity of 99Mo/99mTc generator eluates. Our colorimetric 'spot test' is advantageous for the visual evaluation of Al pertechnetate concentrations as required by Ph. Eur. showing a sensitivity and a limit of detection superior to that of commercially available spot systems.
Related Concept Videos
EDTA: Indirect and Alkalimetric Titration
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...