Related Experiment Video
Updated: May 1, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
How to measure the right ventricular outflow tract with cardiovascular magnetic resonance imaging: a head-to-head
Christina Doesch1, Henrik Michaely, Dariusch Haghi
1First Department of Medicine, University Medical Centre Mannheim, Medical Faculty Mannheim, University of Heidelberg, Germany.
Introduction:
Structural abnormalities of the right ventricular outflow tract (RVOT) have been described in several clinical conditions. The aim of our study was to prospectively compare the available approaches to measuring the RVOT area and diameter by cardiovascular magnetic resonance imaging (CMR) and establish reference values in healthy volunteers. In addition, we sought to introduce a new algorithm for dedicated RVOT area evaluation determined by the RVOT axis.
Methods:
In 50 healthy volunteers CMR was performed to measure the RVOT area: 1) on axial images using turbo spin echo imaging (axial TSE), 2) on steady state free precession (axial SSFP), 3) on short axis slices using SSFP (SAX SSFP), and 4) on a plane determined by the RVOT axis using SSFP (RVOT axis SSFP). Additionally, the RVOT diameter was measured on SSFP SAX images.
Results:
RVOT measurements on axial TSE (8.4 ± 1.4 cm(2)) and on RVOT axis SSFP images were comparable (8.4 ± 0.1 cm(2), p=0.99). The axial SSFP (10.2 ± 1.5 cm(2)) and SAX SSFP (11.0 ± 1.9 cm(2)) images resulted in significantly larger RVOT areas than on the axial TSE images (p<0.0001) and on the RVOT axis SSFP images (p<0.0001). The RVOT diameter measured was 22.4 ± 0.3 mm. RVOT assessment on the axial SSFP and RVOT axis SSFP images revealed the best intra- and interobserver reliability.
Conclusion:
RVOT area measurements differ significantly in healthy volunteers, depending on the imaging plane and technique. In view of the excellent intra- and interobserver reliability and the precise image plane positioning, we recommend the new RVOT axis approach for dedicated RVOT measurements.
More Related Videos
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
10:33Assessment of Right Ventricular Structure and Function in Mouse Model of Pulmonary Artery Constriction by Transthoracic Echocardiography
Published on: February 3, 2014