Related Concept Videos

iChip01:24

iChip

105
The cultivation of environmental microorganisms has long been hindered by the inability to replicate complex native conditions in vitro. The isolation chip (iChip) addresses this limitation by facilitating the growth of previously uncultivable microorganisms through in situ incubation. Designed for high-throughput microbial cultivation, the iChip comprises hundreds of microchambers, each capable of housing a single microbial cell. These microchambers are loaded with a mixture of molten agar and...
105

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Dynamic, minimally invasive electrical brain stimulation improves speech perception.

Hearing research·2026
Same author

Author Correction: Control of spatiotemporal activation of organ-specific fibers in the swine vagus nerve by intermittent interferential current stimulation.

Nature communications·2026
Same author

A fast and simple algorithm for accurate spike detection in HD-MEA recordings.

Journal of neuroscience methods·2026
Same author

A robust, real‑time telemetry protocol for miniaturized neural implants using off‑the‑shelf hardware.

Bioelectronic medicine·2026
Same author

An anhydrobiotic cell line expressing odorant receptors shows odorant responses after dry storage.

Scientific reports·2025
Same author

Control of spatiotemporal activation of organ-specific fibers in the swine vagus nerve by intermittent interferential current stimulation.

Nature communications·2025

Related Experiment Video

Updated: May 1, 2026

High Throughput Microfluidic Rapid and Low Cost Prototyping Packaging Methods
07:51

High Throughput Microfluidic Rapid and Low Cost Prototyping Packaging Methods

Published on: December 23, 2013

7.1K

Packaging commercial CMOS chips for lab on a chip integration.

Timir Datta-Chaudhuri1, Pamela Abshire, Elisabeth Smela

  • 1Department of Electrical and Computer Engineering, 2160 A.V. Williams, College Park, Maryland, USA.

Lab on a Chip
|April 1, 2014
PubMed
Summary

A novel, simple packaging method integrates microelectronic complementary metal oxide semiconductor (CMOS) circuits into lab-on-a-chip (LOC) devices. This technique enables advanced miniaturized sensing systems with biocompatible and reusable packaging.

More Related Videos

Accessible Silicone Chip-to-Membrane Sealing Procedure for Flexible, Reliable Bonding
06:10

Accessible Silicone Chip-to-Membrane Sealing Procedure for Flexible, Reliable Bonding

Published on: March 20, 2026

171
A Microfluidic Chip for ICPMS Sample Introduction
11:16

A Microfluidic Chip for ICPMS Sample Introduction

Published on: March 5, 2015

11.0K

Related Experiment Videos

Last Updated: May 1, 2026

High Throughput Microfluidic Rapid and Low Cost Prototyping Packaging Methods
07:51

High Throughput Microfluidic Rapid and Low Cost Prototyping Packaging Methods

Published on: December 23, 2013

7.1K
Accessible Silicone Chip-to-Membrane Sealing Procedure for Flexible, Reliable Bonding
06:10

Accessible Silicone Chip-to-Membrane Sealing Procedure for Flexible, Reliable Bonding

Published on: March 20, 2026

171
A Microfluidic Chip for ICPMS Sample Introduction
11:16

A Microfluidic Chip for ICPMS Sample Introduction

Published on: March 5, 2015

11.0K

Area of Science:

  • Microfluidics and Integrated Circuitry
  • Biocompatible Packaging for Lab-on-a-Chip Devices
  • Miniaturized Sensing Systems

Background:

  • Lab-on-a-chip (LOC) devices integrate sensing capabilities, reducing reliance on benchtop equipment.
  • Integrating microelectronics, specifically complementary metal oxide semiconductor (CMOS) circuits, onto small LOCs presents significant packaging challenges.
  • Existing packaging methods often struggle with small chip sizes and achieving a level surface for subsequent processing.

Purpose of the Study:

  • To present a simple and adaptable packaging method for embedding foundry-fabricated CMOS dies into LOC devices.
  • To demonstrate the compatibility and functionality of the packaged CMOS sensors for biological applications.
  • To validate the biocompatibility, robustness, and reusability of the developed packaging solution.

Main Methods:

  • Embedding mm-sized CMOS dies into an epoxy handle wafer to create a level, large-area surface.
  • Utilizing thin film metal traces passivated with parylene-C for off-chip electrical connections.
  • Patterning parylene to expose active sensing areas for direct fluidic interaction.

Main Results:

  • Successful packaging of CMOS bioamplifier and capacitance sensor chips, enabling extracellular signal recording and cell monitoring.
  • Demonstrated biocompatibility through long-term cell culture (weeks) on packaged chips.
  • Confirmed package robustness and reusability through extended fluid exposure (months) and repeated sterilization.

Conclusions:

  • The developed packaging method is simple, accommodates various die sizes, and ensures surface leveling for microfluidic integration.
  • The packaging is biocompatible, robust, and reusable, making it suitable for long-term biological sensing applications.
  • This approach facilitates the adoption of miniaturized sensing systems, driving innovation in LOC technology.