A chemometric approach to characterization of ionic liquids for gas chromatography
Jaime González-Álvarez1, Juan José Mangas-Alonso, Pilar Arias-Abrodo
1Department of Physical and Analytical Chemistry, University of Oviedo, Julián Clavería 8, 33006, Oviedo, Spain, gonzalezalvarezjaime@gmail.com.
Abstract:
A chemometric study was carried out to characterize three ionic liquid types (ILs) with hexacationic imidazolium, polymeric imidazolium, and phosphonium cationic cores, using a range of contra-anions such as halogens, thiocyanate, boron anions, triflate, and bistriflimide. The solvation parameter model developed by Abraham et al., unsupervised techniques as cluster analysis (CA), and supervised techniques as linear discriminant analysis (LDA), step-LDA, quadratic discriminant analysis (QDA), and multivariate regression techniques as discriminant partial least squares (D-PLS), or multiple linear regression (MLR) were used to characterize the functionalized ILs above. CA established two main groups of phases, those with an acidic H-bond and those with basic ones. Once detected, the two natural groups, a linear and quadratic delimiters with good classification (>96 %) and prediction (>92 %) capacities were computed. The use of step-LDA technique allowed us to establish that a, b, and s solvation parameters were the most discriminant variables. These variables were used for modeling purposes, and a D-PLS and MLR models were constructed using a binary response. The explained variance of categorical variable by the model validated by cross-validation was 65 %, and 94.5 % of ILs were correctly predicted. IL characterization carried out would allow the appropriate selection of phases for gas chromatography (GC).
More Related Videos
11:04Synthesis of Ionic Liquid Based Electrolytes, Assembly of Li-ion Batteries, and Measurements of Performance at High Temperature
Published on: December 20, 2016
09:44Development, Characterization, and Evaluation of CAGE-based Ionic Liquid Systems for Transdermal Delivery
Published on: September 26, 2025
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Ion-Exchange Chromatography
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...