Related Experiment Video
Updated: May 1, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Nonenhanced renal MR angiography using steady-state free precession (SSFP) and time-spatial labeling inversion pulse
Yuyang Zhang1, Zhen Xing, Ying Liu
1Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Cha-Zhong Road, Fuzhou, 350005, Fujian, China.
Purpose:
To prospectively determine the repeatability of noncontrast-enhanced renal arterial angiography with steady-state free precession (SSFP) and time-spatial labeling inversion pulse (Time-SLIP), and to compare the visibility of renal artery and its branches when different locations of tagging pulse were placed.
Methods:
Thirty-six young healthy volunteers were enrolled in this study and were twice examined by noncontrast-enhanced renal arterial angiography with SSFP and Time-SLIP in 1.5T MR scanner. Measurement error and repeatability were assessed for each of the five major parameters [vessel-to-kidney ratio (VKR), grade of renal arterial branching, grading of image quality, diameter and area of the main renal artery] using the Bland-Altman plot. Two independent observers recorded the values of the parameters; Inter- and intra-observer agreement was assessed using the intraclass correlation coefficients (ICCs). The same parameters, acquired at the tagging pulse placed just above the superior poles of both kidneys or closer to the main renal arteries, were compared using the Wilcoxon signed-rank test.
Results:
Grading of arterial branching by the Time-SLIP SSFP was satisfactorily reproducible with the mean score of greater 3.83 indicating the visibility of branches within the renal parenchyma. The image quality was excellent for Segment I (the main trunk of renal artery) and good for Segment II (segmental branches pre renal parenchyma) and III (vessels within the renal parenchyma) with a satisfying repeatability between two examinations and a good inter- and intra-observer agreement. The ICCs for the inter- and intra-observer measurements of both diameter and area of the main arteries ranged from 0.781 to 0.934, indicating very good agreement. The repeatability of VKR was poor between the two examinations and at the two different tagging pulse locations. The position of tagging pulse in the origination of the main renal arteries was better than in the superior poles of kidneys as it provided a better visualization of arterial branches.
Conclusion:
Noncontrast-enhanced renal artery angiography with SSFP and Time-SLIP yields reliable and reproducible visualization of normal renal arteries. Localization of the tagging pulse closer to the main renal arteries provides better visibility of renal artery and its branches than the tag placement just above the superior poles of both kidneys.
More Related Videos
12:29Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
08:41Assessment of Cardiac Function and Myocardial Morphology Using Small Animal Look-locker Inversion Recovery SALLI MRI in Rats
Published on: July 19, 2013