Coupling of fluorescence correlation spectroscopy with capillary and microchannel analytical systems and its

Chaoqing Dong1, Jicun Ren

  • 1State Key Laboratory of Metal Matrix Composites, School of Chemistry & Chemical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China.

Electrophoresis
|April 2, 2014
PubMed

Related Concept Videos

Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
1.9K
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
1.8K
Supercritical Fluid Chromatography01:18

Supercritical Fluid Chromatography

Supercritical fluid chromatography (SFC) provides a beneficial substitute for gas chromatography (GC) and liquid chromatography (LC) for certain samples because it merges the top attributes of both techniques. SFC allows the separation and analysis of compounds that GC or LC does not easily manage. These compounds are traditionally nonvolatile or thermally unstable, making GC unsuitable and lacking functional groups required for HPLC analysis.
SFC utilizes a supercritical fluid mobile phase,...
1.5K
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
2.1K
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
1.3K
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
16.0K