Related Experiment Video
Updated: May 1, 2026

Instrumentation of Near-term Fetal Sheep for Multivariate Chronic Non-anesthetized Recordings
Published on: October 25, 2015
Does Maturity Affect Cephalic Perfusion and T/QRS Ratio during Prolonged Umbilical Cord Occlusion in Fetal Sheep?
Guido Wassink1, Robert Galinsky1, Paul P Drury1
1Fetal Physiology and Neuroscience Group, Department of Physiology, University of Auckland, Auckland 1023, New Zealand.
Abstract:
T/QRS ratio monitoring is used to help identify fetal asphyxia. However, immature animals have greater capacity to maintain blood pressure during severe asphyxia, raising the possibility that they may show an attenuated T/QRS increase during asphyxia. Chronically instrumented fetal sheep at 0.6 of gestation (0.6 GA; n = 12), 0.7 GA (n = 12), and 0.8 GA (n = 8) underwent complete umbilical cord occlusion for 30 min, 25 min, or 15 min, respectively. Cord occlusion was associated with progressive metabolic acidosis and initial hypertension followed by severe hypotension, with a more rapid fall in mean arterial blood pressure (MAP) and carotid blood flow (CaBF) with advancing gestation. T/QRS ratio rose after occlusion more rapidly at 0.8 GA than in immature fetuses, to a similar final peak at all ages, followed by a progressive fall that was slower at 0.8 GA than in the immature fetuses. The increase in T/QRS ratio correlated with initial hypertension at 0.8 GA (P < 0.05, R (2) = 0.38), and conversely, its fall correlated closely with falling MAP in all gestational groups (P < 0.01, R (2) = 0.67). In conclusion, elevation of the T/QRS ratio is an index of onset of severe asphyxia in the last third of gestation, but not of fetal compromise.