Related Experiment Video
Updated: May 1, 2026

A New Murine Model of Endovascular Aortic Aneurysm Repair
Published on: July 7, 2013
Clinical analysis of non-anastomotic aneurysms of implanted prosthetic grafts
Satoshi Yamamoto1, Katsuyuki Hoshina, Hideo Kimura
1Division of Vascular Surgery, Department of Surgery, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
Purpose:
To investigate the features of non-anastomotic aneurysms (NAAs) of implanted prosthetic grafts through our case series and present a general review of NAAs.
Methods:
We studied retrospectively, a series of NAAs of seven grafts in six patients treated between 2001 and 2010, and reviewed the data on NAAs reported between 1962 and 2009.
Results:
The grafts in our series were implanted between 1986 and 2006. The primary surgical procedures were bypass between the axillary and femoral artery (n = 1), bypass between the subclavian artery and abdominal aorta (n = 1), bypass between the aorta and femoral artery (n = 1), bypass between the femoral and popliteal artery (n = 1), bypass between the femoral and femoral artery (n = 2), and bypass between the aorta and iliac artery (n = 1). The graft material was knitted Dacron in all cases and the implantation period ranged from 2.7 to 24 years (median 13.8 years). All NAAs originated from a hole in the graft. Reports of NAA have decreased dramatically, although according to the data, knitted Dacron accounted for 80 % of these implanted grafts.
Conclusions:
Graft deterioration and the subsequent development of an NAA can occur even with the latest knitted Dacron grafts, even though the incidence is very low.
Related Concept Videos
Aneurysm III: Interprofessional Care
Aneurysm I: Introduction
Aneurysm II: Clinical Manifestations and Diagnostic Studies