Related Experiment Videos

Preparation and application of polyclonal antibodies to recombinant human interleukin-1 alpha and interleukin-1 beta

J C Cornette1, S K Sharma

  • 1Upjohn Company, Kalamazoo, MI 49001.

Journal of Immunoassay
|January 1, 1989
PubMed

We report the preparation and application of polyclonal antisera to the analysis and quantitation of human interleukin-1 alpha (IL-1 alpha) and human interleukin-1 beta (IL-1 beta). The anti IL-1 alpha antibodies specifically react with the alpha form of IL-1 and do not cross react (less than 0.1%) with the beta form of IL-1 and vice versa. Data reported here demonstrate that detection of human IL-1 alpha or beta by a radioimmunoassay technique is sensitive enough to measure picogram levels of these lymphokines. The practical application of using these highly specific antisera for radioimmunoassays was established by measuring exogenously added IL-1 alpha or IL-1 beta to human plasma. Potential benefits of these reagents and the radioimmunoassay procedures described herein are discussed in relation to the biological assays which cannot distinguish between human IL-1 alpha and human IL-1 beta.

Related Concept Videos