Published on: January 12, 2017
Stiffness of the surrounding tissue of breast lesions evaluated by ultrasound elastography
JianQiao Zhou1, WeiWei Zhan, YiJie Dong
1Department of Ultrasound, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, 200025, China.
Objective:
To evaluate the stiffness of the surrounding tissue of breast lesions using the strain ratio assessment method by ultrasound (US) elastography.
Methods:
This was an institutional ethics committee approved prospective study. A total of 127 breast lesions in 118 women (mean age 48.23 ± 14.32, range 20-90) were examined with conventional and elastographic US. The strain ratio assessment method was utilized to semi-quantitatively evaluate the stiffness of the breast lesions and the surrounding tissue.
Results:
Fifty-five lesions were malignant and 72 were benign. The strain ratio of the surrounding tissue was significantly higher in malignant cases (1.49 ± 0.67) than in benign ones (1.17 ± 0.44) (P = 0.001), and yielded an Az value of 0.669 in the diagnosis of breast lesions. There was a significant high positive correlation between the strain ratio of the lesion and the strain ratio of the surrounding tissue in the malignant group (r = 0.740, P < 0.001), and a significant moderate positive correlation in the benign group (r = 0.595, P < 0.001).
Conclusion:
The stiffness of the surrounding tissue of malignant breast lesions was higher than that of benign lesions. The strain ratio of the surrounding tissue and the lesions was significantly correlated, and has potential for breast lesion diagnosis.
Key Points:
• Stiffness of the surrounding tissue of malignant breast lesions was increased. • Stiffness of the surrounding tissue correlated with stiffness of breast lesions. • Stiffness of the surrounding tissue has potential use in diagnosis of breast lesions.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Elastin is Responsible for Tissue Elasticity
Ligaments and tendons are made of dense regular connective tissue, but in ligaments not all fibers are parallel. Dense regular elastic tissue contains elastin fibers and...