Related Experiment Video
Updated: May 1, 2026

Implementation of a Hyperbolic Vortex Plasma Reactor for the Removal of Micropollutants in Water
Published on: July 25, 2025
Removal of phosphorus from wastewaters using ferrous salts - a pilot scale membrane bioreactor study
Yuan Wang1, K Han Tng2, Hao Wu3
1Water Research Centre, School of Civil & Environmental Engineering, University of New South Wales, Sydney 2052 Australia; UNESCO Centre for Membrane Science & Technology, School of Chemical Engineering, University of New South Wales, Sydney 2052 Australia.
Abstract:
A pilot scale membrane bioreactor (3.7 m(3)/day capacity), configured for alternate point ferrous sulphate addition, was evaluated in a fourteen month trial to comply with an effluent discharge requirement of less than 0.15 mg-P/L at the 50(th) percentile and less than 0.30 mg-P/L at the 90th percentile. Ferrous sulphate was added at a molar ratio (Fe(II):PO4) of 2.99 in the filtration chamber for 85 days and 2.60 in the primary anoxic zone for 111 days. Addition of ferrous salts to the anoxic zone achieved a final effluent phosphorous concentration (mg-P/L) of <0.05 (29%), <0.15 (77%) and <0.30 (95%), while addition of ferrous salts in the filtration zone achieved <0.05 (18%), <0.15 (63%) and <0.30 (95%). Analysis of the concentration of iron(II) in the supernatant indicated that phosphorus was mainly removed via adsorption to amorphous iron oxyhydroxides particles in both dosing scenarios. However, analysis of residence time distribution (RTD) data of the reactor indicated that severe short-circuiting from the dosing point to the membrane outlet could occur when the ferrous salts were added to the membrane zone while the reactor behaved close to a completely mixed reactor when dosing to the primary anoxic zone, resulting in improved phosphorus removal. The addition of ferrous salt was also found to delay the onset of severe increase in trans-membrane pressure as a result of the removal of macro-molecules. However, detailed analysis of the form and concentration of iron species in the supernatant and permeate indicated that the presence of fine iron particles resulted in a higher fouling rate when Fe(II) was added to the membrane zone rather than the primary anoxic zone and could cause more severe irreversible fouling in long-term operation.
More Related Videos
08:21Optimized Procedure for Determining the Adsorption of Phosphonates onto Granular Ferric Hydroxide using a Miniaturized Phosphorus Determination Method
Published on: May 18, 2018
05:40Comparison of Scale in a Photosynthetic Reactor System for Algal Remediation of Wastewater
Published on: March 6, 2017
Related Concept Videos
Factors Affecting Solubility
Microbial Bioremediation of Uranium
Bioreactor Design and Operational System
Microbial Leaching