Microelectrode Array Recording of Sinoatrial Node Firing Rate to Identify Intrinsic Cardiac Pacemaking Defects in Mice
Published on: July 5, 2021
Synchronization of sinoatrial node pacemaker cell clocks and its autonomic modulation impart complexity to heart
Yael Yaniv1, Ismayil Ahmet2, Jie Liu3
1Laboratory of Cardiovascular Science, Biomedical Research Center, Intramural Research Program, National Institute on Aging, National Institutes of Health, Baltimore, Maryland; Biomedical Engineering Faculty, Technion-IIT, Haifa, Israel.
Background:
A reduction of complexity of heart beating interval variability that is associated with an increased morbidity and mortality in cardiovascular disease states is thought to derive from the balance of sympathetic and parasympathetic neural impulses to the heart. However, rhythmic clocklike behavior intrinsic to pacemaker cells in the sinoatrial node (SAN) drives their beating, even in the absence of autonomic neural input.
Objective:
To test how this rhythmic clocklike behavior intrinsic to pacemaker cells interacts with autonomic impulses to the heart beating interval variability in vivo.
Methods:
We analyzed beating interval variability in time and frequency domains and by fractal and entropy analyses: (1) in vivo, when the brain input to the SAN is intact; (2) during autonomic denervation in vivo; (3) in isolated SAN tissue (ie, in which the autonomic neural input is completely absent); (4) in single pacemaker cells isolated from the SAN; and (5) after autonomic receptor stimulation of these cells.
Results:
Spontaneous beating intervals of pacemaker cells residing in the isolated SAN tissue exhibit fractal-like behavior and have lower approximate entropy compared with those in the intact heart. Isolation of pacemaker cells from SAN tissue, however, leads to a loss in the beating interval order and fractal-like behavior. β-Adrenergic receptor stimulation of isolated pacemaker cells increases intrinsic clock synchronization, decreases their action potential period, and increases system complexity.
Conclusions:
Both the average beating interval in vivo and beating interval complexity are conferred by the combined effects of clock periodicity intrinsic to pacemaker cells and their response to autonomic neural input.
More Related Videos
08:52Generation of Murine Cardiac Pacemaker Cell Aggregates Based on ES-Cell-Programming in Combination with Myh6-Promoter-Selection
Published on: February 17, 2015
09:32Methods for the Isolation, Culture, and Functional Characterization of Sinoatrial Node Myocytes from Adult Mice
Published on: October 23, 2016
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Electrophysiology of Normal Cardiac Rhythm
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
Regulation of Pulse