Background:
Positron emission tomography-computed tomography (PET-CT) with (18)F-fluorodeoxyglucose (FDG) has emerged as a rapidly evolving diagnostic tool for infectious diseases. However, the optimal imaging time in this clinical setting is not clear yet. The aim of this study is to investigate whether delayed (3 hours) FDG PET-CT could increase the diagnostic accuracy of this technique compared to standard (1 hour) imaging in the detection of septic foci involving the pocket and/or pacing leads in patients with suspected cardiovascular implantable electronic device (CIED) infection scheduled for device removal.
Methods And Results:
Twenty-seven patients underwent standard and delayed imaging. PET-CT results were compared to bacteriological cultures after CIED removal. Fifteen controls free of infection underwent PET-CT imaging as part of investigation of malignancy. The diagnostic accuracy of delayed imaging was significantly higher than 1-hour scan for lead infection (70% vs 51%, P = .024). No significant difference was found between standard and delayed diagnostic accuracy for pocket or device infection. Semi-quantitative analysis showed that mean pocket and lead target-to-background ratio were significantly higher on delayed compared to standard imaging (3.7 ± 1.9 vs 1.6 ± 1.1, P = .0002; 3.0 ± 1.3 vs 0.7 ± 1.0, P = .01).
Conclusions:
Delayed FDG PET-CT imaging should be considered at least in patients with negative 1-hour scan and founded suspicion of pacing lead infection.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...