Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

7.6K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
7.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Thalamic deep brain stimulation in traumatic brain injury: a phase 1, randomized feasibility study.

Nature medicine·2023
Same author

Thalamic nuclei atrophy at high and heterogenous rates during cognitively unimpaired human aging.

NeuroImage·2022
Same author

Stretchable self-tuning MRI receive coils based on liquid metal technology (LiquiTune).

Scientific reports·2021
Same author

Electric field calculation and peripheral nerve stimulation prediction for head and body gradient coils.

Magnetic resonance in medicine·2021
Same author

Minimum electric-field gradient coil design: Theoretical limits and practical guidelines.

Magnetic resonance in medicine·2021
Same author

Correlative Microscopy to Localize and Characterize Iron Deposition in Alzheimer's Disease.

Journal of Alzheimer's disease reports·2021

Related Experiment Video

Updated: May 1, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

18.6K

Practical methods for improving B1+ homogeneity in 3 Tesla breast imaging.

Simone A Winkler1, Brian K Rutt

  • 1Department of Radiology, Stanford University, Stanford, California, USA.

Journal of Magnetic Resonance Imaging : JMRI
|April 12, 2014
PubMed
Summary

This study explores two practical ways to improve image quality in 3 Tesla breast MRI by correcting magnetic field variations. Researchers tested passive dielectric pads and active radiofrequency shimming, finding that both methods significantly reduce field asymmetry and improve image uniformity without compromising patient safety.

Keywords:
B+1 inhomogeneityB1 mappingRF shimmingbreast cancerdielectric shimmingmagnetic resonance imagingradiofrequency shimmingdielectric permittivityimage quality enhancement

Frequently Asked Questions

More Related Videos

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
15:48

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging

Published on: December 15, 2014

25.0K
Clinical Imaging of Microwave Mammography
05:28

Clinical Imaging of Microwave Mammography

Published on: November 14, 2025

445

Related Experiment Videos

Last Updated: May 1, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

18.6K
Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
15:48

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging

Published on: December 15, 2014

25.0K
Clinical Imaging of Microwave Mammography
05:28

Clinical Imaging of Microwave Mammography

Published on: November 14, 2025

445

Area of Science:

  • Medical physics and B1+ homogeneity optimization in diagnostic imaging
  • Radiology and breast magnetic resonance imaging research

Background:

Magnetic resonance imaging at high field strengths often suffers from significant signal intensity variations across the breast. This lack of uniformity complicates diagnostic interpretation and reduces the reliability of tissue characterization. Prior research has shown that dielectric properties of human tissue distort the radiofrequency field. That uncertainty drove the need for effective correction strategies to stabilize signal distribution. Standard clinical protocols frequently struggle to maintain consistent image quality across diverse patient anatomies. This gap motivated the development of specialized hardware and software adjustments. Previous attempts to mitigate these distortions often required complex setups or expensive equipment modifications. No prior work had resolved these challenges using simple, accessible, and safe clinical approaches.

Purpose Of The Study:

The aim of this research is to evaluate practical strategies for enhancing signal uniformity in 3 Tesla breast magnetic resonance imaging. High-field systems often produce uneven radiofrequency fields, which degrade the quality of diagnostic images. This study addresses the specific problem of field asymmetry that limits the accuracy of breast tissue assessment. Researchers sought to determine if passive dielectric pads could effectively mitigate these signal variations. They also investigated whether two-channel radiofrequency shimming could provide a reliable alternative or complementary solution. The motivation stems from the need for simple, safe, and effective methods to improve clinical imaging outcomes. By testing these techniques in both simulations and human subjects, the team aimed to provide a clear validation of their performance. This work focuses on establishing accessible solutions that do not require complex hardware changes.

Main Methods:

Review approach involved testing two distinct correction techniques within a 3 Tesla magnetic resonance environment. Investigators utilized passive dielectric pads with varying permittivity levels to alter the local electromagnetic field. The team also employed two-channel radiofrequency shimming by modifying amplitude ratios and phase differences. Researchers conducted numerical simulations using a body model populated with mammary tissue to predict performance. Six human subjects participated in the in vivo phase to validate the simulated outcomes. The study evaluated the effectiveness of each method individually and in combination. Analysts monitored radiofrequency safety parameters throughout all experimental procedures to ensure compliance. This comprehensive framework allowed for a thorough comparison between the proposed hardware and software solutions.

Main Results:

Key findings from the literature indicate that both strategies significantly enhance field uniformity during breast examinations. The passive dielectric approach and the active radiofrequency shimming technique both successfully reduced signal asymmetry. In simulated models, the left-right asymmetry ratio improved from 1.24 to 1.00. Human testing showed a corresponding decrease in the asymmetry ratio from 1.26 to 1.01. These improvements occurred without causing any adverse effects on radiofrequency safety profiles. The combined application of both methods yielded robust results across all tested scenarios. Data confirm that these practical interventions effectively address the inherent field distortions common in high-field breast scans. The results consistently demonstrate that these simple modifications provide substantial benefits for image quality.

Conclusions:

The researchers demonstrate that both passive and active strategies effectively mitigate signal distortions in breast examinations. Synthesis and implications suggest that these techniques offer a viable path for enhancing diagnostic precision. Both approaches successfully reduced the asymmetry ratio between left and right sides in simulated and human models. The findings indicate that these adjustments do not negatively impact established radiofrequency safety limits. Integrating these methods into routine clinical workflows could improve the consistency of breast imaging results. The evidence supports the use of dielectric pads or dual-channel phase adjustments to stabilize the field. Authors emphasize that these practical solutions provide robust performance without requiring major system overhauls. Future clinical implementation may benefit from the combined application of these two distinct correction modalities.

The researchers propose that adjusting the amplitude ratios and phase differences between two radiofrequency channels corrects field distortions. This active approach, alongside passive dielectric pads, successfully reduced the left-right asymmetry ratio from 1.26 to 1.01 in human subjects.

Dielectric pads with permittivity values ranging from 0 to 100 serve as a passive tool. These components manipulate the local electromagnetic environment to counteract signal drop-off, contrasting with the active electronic phase adjustments used in the dual-channel radiofrequency method.

A numerical body model incorporating mammary tissue was necessary to validate the techniques before human testing. This computational environment allowed for precise control over variables, ensuring that the passive and active correction strategies were safe and effective prior to clinical application.

The study utilized a combination of simulation data and in vivo measurements from six subjects. This dual-data approach ensures that the findings are both theoretically sound and practically applicable to real-world patient imaging scenarios.

The researchers measured the left-right B1+ asymmetry ratio as the primary indicator of field homogeneity. Improvements were observed across both methods, with the ratio dropping from 1.24 to 1.00 in simulations and 1.26 to 1.01 in human subjects.

The authors suggest that these methods maintain radiofrequency safety standards. They conclude that implementing these practical adjustments does not adversely affect patient safety, making them suitable for potential integration into standard clinical breast imaging protocols.